14
47
5.2 Plus Systems Incorporating BA-ICE-CM Controller
5.2.1 UV Intensity (%)
The VIQUA Plus series of products incorporate a UV sensor which detects the discrete 254 nm wavelength of the
UV lamp. This information is relayed to the VIQUA controller and is the default display shown in “% UV output”. The system
will display the UV output between 50 to 99 percent. When the system drops below 50%, a low UV warning is displayed as
and alternately flashes (at 2 second intervals) back to the actual UV level. Eg.
. Additionally, the system will
sound an intermittent audible tone (2 seconds on, 2 seconds off), during low UV conditions.
Note: UV levels of
DEFERRAL
- To temporarily defer the audible alarm and re-activate solenoid valve (if fitted) during a low UV alarm, press
the timer reset button and hold for five seconds. This will mute the audible alarm condition and activate solenoid output for
12 hours.
Over Temperature
- When the water temperature inside the UV reactor chamber exceeds the maximum rating for the UV
system (40 °C) the Controller will show “Ot” on the display. This is usually caused by extended periods of no water flow.
To clear this condition simply open a faucet and allow water to flow through the system.
Possible causes for low UV alarm conditions:
a.
The UV lamp has perhaps reached a level whereby it can no longer adequately provide a sufficient level of
disinfection due to age (> 9000 hours). The lamp should be replaced with a new lamp from the manufacturer of the
same size and type.
b.
The quartz sleeve and/or the sensor window have become stained or dirty. Mineral deposits or sediment in the water
that was not detected during the original water analysis may be the cause for this. Refer to
.
c.
Intermittent voltage drop in the household controller reducing the lamp output. The lamp will return to normal when
the power is restored to full voltage.
Note: The monitoring system will not operate during power failures.
d.
The quality of the influent water has changed and is no longer within the acceptable operational range of the UV
system. Perform a water analysis to determine the exact constituents and concentration levels.
e.
The UV sensor is not installed correctly.
5.2.2 Lamp Life Remaining (Days)
To obtain this reading, press the timer reset button a single time and follow the steps as outlined in
regarding the operation of this feature.
to
Indicates the system is functioning within a normal operating range.
to
Indicates the UV level is still within a safe level, however cleaning or lamp/sleeve replacement may soon
be required.
to
Indicates the UV level is nearing the point of unsafe UV intensity, UV system should be immediately
serviced.
<
Indicates the UV level has now reached a level that is unsafe. At this level the water should not be
consumed. The system/water supply should be examined to determine the reason for the low UV level
of the UV intensity. At this level, the solenoid output has been activated and if a solenoid is installed,
water will cease to flow.
Instalación
2.
Seleccione una ubicación adecuada para el sistema de desinfección y sus componentes relacionados. Como se
recomienda instalar un GFCI, asegúrese de que esto se tiene en cuenta antes de cualquier instalación. El sistema se
puede instalar en posición vertical (con el puerto de entrada abajo) como se indica en
A
o en posición
horizontal, como se indica en
B
. Pero el método de preferencia es el de la instalación vertical. Cuando
seleccione una ubicación de montaje, deje suficiente espacio para que se pueda extraer la lámpara UV o la vaina
tubular de cuarzo (normalmente se debe dejar un espacio del tamaño de la cámara).
3.
Monte el sistema en la pared con las grapas suministradas. Para conectar la fuente de agua al sistema se pueden usar
varios métodos de conexión, sin embargo, se recomiendan los conectores de unión. El uso de un dispositivo limitador
del caudal ayuda a mantener el caudal nominal del fabricante. El limitador de caudal debe instalarse en el puerto de
salida y está diseñado para instalarse en una sola dirección. Asegúrese de que el flujo del agua coincide con la
dirección de flujo indicada en el limitador de caudal. Consulte
.
Nota: NO suelde las conexiones mientras estén sujetas al sistema ya que podría dañar las juntas tóricas.
4.
Monte el controlador VIQUA ICE de forma horizontal a la pared, cerca de la cámara. Lo ideal sería colocar el
controlador sobre la cámara y lejos de cualquier punto de conexión de agua para evitar que se vierta agua en el
controlador por medio de fugas en un punto de conexión o un sistema de "transpiración". Asegúrese de permitir un
"bucle de goteo", como se muestra en la
, en la lámpara, el sensor y el cable de alimentación para evitar,
de nuevo, que entre agua en el controlador.
Figura 3 Instalación del sistema de desinfección: vertical y horizontal
Figura 4 Limitador de caudal
A
B
Longitud total
de la unidad
Holgura mín. igual
a la longitud total
de la unidad
Longitud total
de la unidad
Holgura mín. igual
a la longitud total
de la unidad
Limitador
de caudal
Válvula de
temperatura opcional
Flujo
Operation
Содержание VH200
Страница 21: ...This page intentionally left blank ...
Страница 22: ...This page intentionally left blank ...
Страница 23: ...This page intentionally left blank ...