background image

© 2004 Directed Electronics, Inc. Vista, CA

5

5

Connect this wire directly to the domelight circuit in the vehicle. The on-board relay will drive circuits up

to 20 amperes. The polarity of this output is determined by the connection of the H2/A input wire in the

Auxiliary Harness.

N

NO

OTTEE::  If the H2/A input wire is not connected, there will be no output on this wire.

Most vehicles use negative door trigger circuits. Connect the green wire to a wire which shows ground when any

door is opened. In vehicles with factory delays on the domelight circuit, there is usually a wire that is unaffected

by the delay circuitry. This wire will report Zone 3.

This wire will respond to a negative input with an instant trigger. Inputs shorter than 0.8 seconds will trigger

the Warn Away response, while triggers longer than 0.8 seconds will instantly trigger the full alarm cycle. This

wire is ideal for hood and trunk pins and will report on Zone 1. This wire can also be used with Directed

Electronic’s 506T Glass Breakage Sensor, as well as other Directed Electronic’s single stage sensors. The H1/6 BLUE

multiplex trigger wire can be used to shunt sensors during operation, using the auxiliary channels. When any of

the auxiliary channels are transmitted, the H1/6 BLUE wire monitors for a ground. If ground is detected within

5 seconds of transmission, the sensors and the multiplex trigger input on the BLUE wire will be shunted until 5

seconds after the ground is removed. This allows the customer to access the trunk, remote start the vehicle, or

roll the windows down without first disarming the alarm. (See 

Bypassing Sensor Inputs section of this guide.)

H

H1

1//6

6  B

BLLU

UEE  ((--))  m

mu

ullttiip

plleexx  ttrriig

gg

geerr  iin

np

pu

utt,,  zzo

on

nee  1

1

H

H1

1//5

5  G

GR

REEEEN

N  ((--))  d

do

oo

orr  ttrriig

gg

geerr  iin

np

pu

utt,,  zzo

on

nee  3

3

H

H1

1//4

4  B

BLLA

ACCK

K//W

WH

HIITTEE  h

hiig

gh

h  ccu

urrrreen

ntt  o

ou

uttp

pu

utt  ffrro

om

m  o

on

n--b

bo

oaarrd

d  iin

ntteerriio

orr  lliig

gh

htt  iillllu

um

miin

naattiio

on

n  rreellaayy

Содержание 320HV

Страница 1: ...M Mo od de ell 3 32 20 0H HV V I In ns st ta alllla at tiio on n G Gu uiid de e 2004 Directed Electronics Inc Vista CA N431V 07 04 V VIIP PE ER R...

Страница 2: ...e multiplex 16 type H negative multiplex 18 p pl lu ug g i in n L LE ED D a an nd d v va al le et t p pr ro og gr ra am m s sw wi it tc ch h 2 23 3 i in nt te er rn na al l p pr ro og gr ra am mm mi i...

Страница 3: ...LI ID DI IT TY Y O OU UT TP PU UT T R RE ED D 1 12 2V V C CO ON NS ST TA AN NT T P PO OW WE ER R I IN NP PU UT T B BR RO OW WN N S SI IR RE EN N O OU UT TP PU UT T Y YE EL LL LO OW W I IG GN NI IT TI...

Страница 4: ...Internal Programming Jumper section of this guide P P N N 8 86 61 17 7 or a standard automotive SPDT relay must be used on the H1 2 light flash output harness wire This wire provides a 200 mA output w...

Страница 5: ...This wire can also be used with Directed Electronic s 506T Glass Breakage Sensor as well as other Directed Electronic s single stage sensors The H1 6 BLUE multiplex trigger wire can be used to shunt s...

Страница 6: ...on source This input must show 12V with the key in run position and during cranking Make sure that this wire cannot be shorted to the chassis at any point This wire will report Zone 5 Connect this to...

Страница 7: ...er than 1 5 seconds the red white wire will supply an output as long as the transmission continues This is often used to operate a trunk hatch release or other relay driven function I IM MP PO OR RT T...

Страница 8: ...n the driver s door or on the center console Once you have determined which type of factory door lock circuit you are working with and the color codes of the switch wires to be used you can usually si...

Страница 9: ...cuum systems The vehicle must have a vacuum actuator in each door Make sure that locking the doors from the driver s or passenger side using the key activates all the actuators in the vehicle This req...

Страница 10: ...1 10 0 2004 Directed Electronics Inc Vista CA t ty yp pe e A A p po os si it ti iv ve e t tr ri ig gg ge er re ed d r re el la ay y d dr ri iv ve en n s sy ys st te em m...

Страница 11: ...pe B The switch will have three wires on it and one wire will test ground all the time One wire will pulse when the switch locks the doors and the other wire will pulse when the switch unlocks the doo...

Страница 12: ...1 12 2 2004 Directed Electronics Inc Vista CA t ty yp pe e C C r re ev ve er rs si in ng g p po ol la ar ri it ty y s sy ys st te em m...

Страница 13: ...door This requires mount ing the door lock actuator inside the door Other vehicles may only require one actuator installed in the driver s door if all door locks are operated when the driver s lock is...

Страница 14: ...vated vacuum pump The control wire will show 12V when doors are unlocked and ground when locked N NO OT TE E The system must be programmed for 3 5 second door lock pulses and the violet jumper between...

Страница 15: ...hese are reversed It is found in the late model Nissan Sentras some Nissan 240SX Nissan 300ZX 1992 and later It is also found in some Mazda MPV s N NO OT TE E The violet jumper between the 87 lock ter...

Страница 16: ...tch key cylinder must be isolated from the factory door lock system For testing use a calibrated digital multimeter that is set to ohms I IM MP PO OR RT TA AN NT T To ensure an accurate resistance rea...

Страница 17: ...2004 Directed Electronics Inc Vista CA 1 17 7...

Страница 18: ...the resistor values the door lock switch key cylinder must be isolated from the factory door lock system For testing use a calibrated digital multimeter that is set to ohms I IM MP PO OR RT TA AN NT...

Страница 19: ...lock output is used to unlock the passenger doors N NO OT TE E The second unlock output feature is not available if the double pulse unlock feature is turned on I IM MP PO OR RT TA AN NT T The H2 A wi...

Страница 20: ...2 20 0 2004 Directed Electronics Inc Vista CA D Dr ri iv ve er r s s D Do oo or r U Un nl lo oc ck k O On nl ly y T Ty yp pe e A A...

Страница 21: ...a single pulse when armed and two pulses when disarmed This wire also provides pulsed output when the security system is in the triggered sequence or in panic mode In most vehicle s with horn circuits...

Страница 22: ...he addition of the relay accessory package p p n n 8 86 61 17 7 s st ta ar rt te er riin nt te er rr ru up pt th ha ar rn ne es ss s H H4 4 w wiir re ec co on nn ne ec ct tiio on ng gu uiid de e _____...

Страница 23: ...y ys st te em m S St ta at tu us s I In nd di ic ca at to or r V Va al le et t P Pr ro og gr ra am m S Sw wi it tc ch h iin nt te er rn na all p pr ro og gr ra am mm miin ng g jju um mp pe er r This j...

Страница 24: ...om N NO OT TE E When adjusting the sensor it must be mounted in the same location where it will be after the installation is completed Adjusting the sensor and then relocating the module requires read...

Страница 25: ...for programming There is a basic sequence to remember whenever programming this unit Door Key Choose Transmit and Release 1 O Op pe en n a a d do oo or r The GREEN wire H1 5 or the VIOLET H1 7 must be...

Страница 26: ...Learning has been exited if any of the following occurs Ignition is turned off The doors are closed Valet Program switch is pressed too many times More than 15 seconds elapses between steps C CH HA AN...

Страница 27: ...operates Panic Button operates Trunk Silent Arm Disarm Channel Two Buttons operates Channel Three Buttons operates Channel Four 4 4 b bu ut tt to on n t tr ra an ns sm miit tt te er r c co on nf fiig...

Страница 28: ...the Valet Program switch you can select the desired features setting using the remote transmitter Pressing the lock icon transmitter button while H HO OL LD DI IN NG G down the Valet Program switch w...

Страница 29: ...TT TI IN NG GS S N NU UM MB BE ER R P PR RE ES SS S L LO OC CK K I IC CO ON N T TR RA AN NS SM MI IT TT TE ER R B BU UT TT TO ON N P PR RE ES SS S U UN NL LO OC CK K I IC CO ON N T TR RA AN NS SM MI...

Страница 30: ...erface with double pulse vehicles without any extra parts N NO OT TE E The second unlock output feature H3 1 BLUE wire is not available if the double pulse unlock feature is turned on 7 7 S ST TE EA A...

Страница 31: ...void any false triggering of the system while the window are in motion n nu uiis sa an nc ce e p pr re ev ve en nt tiio on n c ciir rc cu uiit tr ry y NPC requires that you change the way you test the...

Страница 32: ...of door switch system This often happens when the wrong door input has been used See H1 5 GREEN Door Trigger Input Primary Harness Wire Connection Guide section of this guide S Sy ys st te em m w wi...

Страница 33: ...w wi it tc ch h d do oe es s n no ot t w wo or rk k Is it plugged into the correct socket See Plug In LED and Valet Program Switch section of this guide T Th he e L LE ED D s sy ys st te em m s st ta...

Страница 34: ...put Zone 3 Black Chassis Ground Brown Siren output 1A Red Constant Power Red White 200 mA Channel 2 Auxiliary Output Chassis Ground Optional Accessories Domelight Optional Negative Door Pin Switch Neg...