background image

2

28

8

© 2004 Directed Electronics, Inc. Vista, CA

ssyysstteem

m  ffeeaattuurreess  lleeaarrnn  rroouuttiinnee

Many of the features of this unit are programmable. They can be changed whenever necessary through this learn

routine. The Valet

®

/Program switch, plugged into the blue port, is used together with a programmed transmitter

to change the settings. 

TTo

o  een

ntteerr  tth

hee  ffeeaattu

urree  lleeaarrn

n  rro

ou

uttiin

nee::

1. 

O

Op

peen

n  aa  d

do

oo

orr..  ((The GREEN wire, H1/5, or the VIOLET, H1/7 must be connected.)

2. 

IIg

gn

niittiio

on

n..  Turn the ignition on, then back off. (The H1/9 YELLOW switched ignition input

must be connected.) 

2.

CCh

ho

oo

ossee..   Within 10 seconds, press and release the Valet

®

/Program switch the number of

times corresponding to the feature number you want to program (see the 

Features Menu

section of this guide). Then press the switch once more and hold it.

The LED will flash and the siren will chirp to indicate which feature you have accessed.

4.

TTrraan

nssm

miitt..   While  H

HO

OLLD

DIIN

NG

G the Valet

®

/Program switch, you can select the desired features

setting using the remote transmitter. Pressing the lock icon transmitter button while

H

HO

OLLD

DIIN

NG

G down the Valet/Program switch will program the feature to the LED ON (default)

setting. The siren will chirp once. Pressing the unlock icon transmitter button while

H

HO

OLLD

DIIN

NG

G down the Valet/Program switch will change the setting to the LED OFF setting.

The siren will chirp twice.

5. 

R

Reelleeaassee..  Release the Valet

®

/Program switch.

TTo

o  aacccceessss  aan

no

otth

heerr  ffeeaattu

urree::

You can advance from feature to feature by pressing and releasing the Valet

®

/Program switch the number of times

necessary to get from the feature you just programmed to the feature you wish to access. For example, if you

just programmed Feature 1 and you want to program Feature 2:

1. Release the Valet

®

/Program switch.

2. Press and release the Valet/Program switch once to advance from Feature 1 to Feature 2.

3. Press the Valet

®

/Program switch once more and H

HO

OLLD

D it.

4. The siren will chirp two times to confirm that you have accessed Feature 2.

TTo

o  eexxiitt  tth

hee  CCo

od

dee  LLeeaarrn

niin

ng

g,,  d

do

o  o

on

nee  o

off  tth

hee  ffo

ollllo

ow

wiin

ng

g::

Содержание 320HV

Страница 1: ...M Mo od de ell 3 32 20 0H HV V I In ns st ta alllla at tiio on n G Gu uiid de e 2004 Directed Electronics Inc Vista CA N431V 07 04 V VIIP PE ER R...

Страница 2: ...e multiplex 16 type H negative multiplex 18 p pl lu ug g i in n L LE ED D a an nd d v va al le et t p pr ro og gr ra am m s sw wi it tc ch h 2 23 3 i in nt te er rn na al l p pr ro og gr ra am mm mi i...

Страница 3: ...LI ID DI IT TY Y O OU UT TP PU UT T R RE ED D 1 12 2V V C CO ON NS ST TA AN NT T P PO OW WE ER R I IN NP PU UT T B BR RO OW WN N S SI IR RE EN N O OU UT TP PU UT T Y YE EL LL LO OW W I IG GN NI IT TI...

Страница 4: ...Internal Programming Jumper section of this guide P P N N 8 86 61 17 7 or a standard automotive SPDT relay must be used on the H1 2 light flash output harness wire This wire provides a 200 mA output w...

Страница 5: ...This wire can also be used with Directed Electronic s 506T Glass Breakage Sensor as well as other Directed Electronic s single stage sensors The H1 6 BLUE multiplex trigger wire can be used to shunt s...

Страница 6: ...on source This input must show 12V with the key in run position and during cranking Make sure that this wire cannot be shorted to the chassis at any point This wire will report Zone 5 Connect this to...

Страница 7: ...er than 1 5 seconds the red white wire will supply an output as long as the transmission continues This is often used to operate a trunk hatch release or other relay driven function I IM MP PO OR RT T...

Страница 8: ...n the driver s door or on the center console Once you have determined which type of factory door lock circuit you are working with and the color codes of the switch wires to be used you can usually si...

Страница 9: ...cuum systems The vehicle must have a vacuum actuator in each door Make sure that locking the doors from the driver s or passenger side using the key activates all the actuators in the vehicle This req...

Страница 10: ...1 10 0 2004 Directed Electronics Inc Vista CA t ty yp pe e A A p po os si it ti iv ve e t tr ri ig gg ge er re ed d r re el la ay y d dr ri iv ve en n s sy ys st te em m...

Страница 11: ...pe B The switch will have three wires on it and one wire will test ground all the time One wire will pulse when the switch locks the doors and the other wire will pulse when the switch unlocks the doo...

Страница 12: ...1 12 2 2004 Directed Electronics Inc Vista CA t ty yp pe e C C r re ev ve er rs si in ng g p po ol la ar ri it ty y s sy ys st te em m...

Страница 13: ...door This requires mount ing the door lock actuator inside the door Other vehicles may only require one actuator installed in the driver s door if all door locks are operated when the driver s lock is...

Страница 14: ...vated vacuum pump The control wire will show 12V when doors are unlocked and ground when locked N NO OT TE E The system must be programmed for 3 5 second door lock pulses and the violet jumper between...

Страница 15: ...hese are reversed It is found in the late model Nissan Sentras some Nissan 240SX Nissan 300ZX 1992 and later It is also found in some Mazda MPV s N NO OT TE E The violet jumper between the 87 lock ter...

Страница 16: ...tch key cylinder must be isolated from the factory door lock system For testing use a calibrated digital multimeter that is set to ohms I IM MP PO OR RT TA AN NT T To ensure an accurate resistance rea...

Страница 17: ...2004 Directed Electronics Inc Vista CA 1 17 7...

Страница 18: ...the resistor values the door lock switch key cylinder must be isolated from the factory door lock system For testing use a calibrated digital multimeter that is set to ohms I IM MP PO OR RT TA AN NT...

Страница 19: ...lock output is used to unlock the passenger doors N NO OT TE E The second unlock output feature is not available if the double pulse unlock feature is turned on I IM MP PO OR RT TA AN NT T The H2 A wi...

Страница 20: ...2 20 0 2004 Directed Electronics Inc Vista CA D Dr ri iv ve er r s s D Do oo or r U Un nl lo oc ck k O On nl ly y T Ty yp pe e A A...

Страница 21: ...a single pulse when armed and two pulses when disarmed This wire also provides pulsed output when the security system is in the triggered sequence or in panic mode In most vehicle s with horn circuits...

Страница 22: ...he addition of the relay accessory package p p n n 8 86 61 17 7 s st ta ar rt te er riin nt te er rr ru up pt th ha ar rn ne es ss s H H4 4 w wiir re ec co on nn ne ec ct tiio on ng gu uiid de e _____...

Страница 23: ...y ys st te em m S St ta at tu us s I In nd di ic ca at to or r V Va al le et t P Pr ro og gr ra am m S Sw wi it tc ch h iin nt te er rn na all p pr ro og gr ra am mm miin ng g jju um mp pe er r This j...

Страница 24: ...om N NO OT TE E When adjusting the sensor it must be mounted in the same location where it will be after the installation is completed Adjusting the sensor and then relocating the module requires read...

Страница 25: ...for programming There is a basic sequence to remember whenever programming this unit Door Key Choose Transmit and Release 1 O Op pe en n a a d do oo or r The GREEN wire H1 5 or the VIOLET H1 7 must be...

Страница 26: ...Learning has been exited if any of the following occurs Ignition is turned off The doors are closed Valet Program switch is pressed too many times More than 15 seconds elapses between steps C CH HA AN...

Страница 27: ...operates Panic Button operates Trunk Silent Arm Disarm Channel Two Buttons operates Channel Three Buttons operates Channel Four 4 4 b bu ut tt to on n t tr ra an ns sm miit tt te er r c co on nf fiig...

Страница 28: ...the Valet Program switch you can select the desired features setting using the remote transmitter Pressing the lock icon transmitter button while H HO OL LD DI IN NG G down the Valet Program switch w...

Страница 29: ...TT TI IN NG GS S N NU UM MB BE ER R P PR RE ES SS S L LO OC CK K I IC CO ON N T TR RA AN NS SM MI IT TT TE ER R B BU UT TT TO ON N P PR RE ES SS S U UN NL LO OC CK K I IC CO ON N T TR RA AN NS SM MI...

Страница 30: ...erface with double pulse vehicles without any extra parts N NO OT TE E The second unlock output feature H3 1 BLUE wire is not available if the double pulse unlock feature is turned on 7 7 S ST TE EA A...

Страница 31: ...void any false triggering of the system while the window are in motion n nu uiis sa an nc ce e p pr re ev ve en nt tiio on n c ciir rc cu uiit tr ry y NPC requires that you change the way you test the...

Страница 32: ...of door switch system This often happens when the wrong door input has been used See H1 5 GREEN Door Trigger Input Primary Harness Wire Connection Guide section of this guide S Sy ys st te em m w wi...

Страница 33: ...w wi it tc ch h d do oe es s n no ot t w wo or rk k Is it plugged into the correct socket See Plug In LED and Valet Program Switch section of this guide T Th he e L LE ED D s sy ys st te em m s st ta...

Страница 34: ...put Zone 3 Black Chassis Ground Brown Siren output 1A Red Constant Power Red White 200 mA Channel 2 Auxiliary Output Chassis Ground Optional Accessories Domelight Optional Negative Door Pin Switch Neg...