n
At
interrupt function
, the counter starts counting with the last recent counter value
after gate restart.
Counter 0 ... 2
SW gate
Gate function
Reaction counter 0 ... 2
Edge 0-1
Abort count process
Restart with
load value
Edge 0-1
Interrupt count process
Continue
5.6.6.3
Comparator
In the CPU a
comparison value
may be stored. During the counting procedure the
counter value is compared with the
comparative value
. Depending on the result of the
comparison the output channel of the counter and the status bit of STS_CMP of SFB 47
can be set. In addition, you can configure a hardware interrupt. A
comparison value
can
be specified via the parametrization respectively the job interface of SFB 47.
Function
VIPA System SLIO
Deployment I/O periphery
Counting > Counter - Additional functions
HB300 | CPU | 013-CCF0R00 | en | 17-20
120