Disassembly
©2010 Viking Preferred Service
37
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Main Top Removal
Condition Requirements:
Control Panel Assembly Removed
Island Trim or Backguard Assembly Removed
Note:
Remove grill and griddle parts on models
equipped with surface grills and/or griddles.
1. Remove grates, burner caps, and burner heads from
each burner base assembly.
2. Mark and disconnect ignition wire from each IRIS
module.
3. Remove two screws from each burner base
assembly.
4. Lift each burner base assembly up to remove from
range.
Note:
Keep igniter wires attached to each burner base
assembly.
5. Remove two screws and side trim from each side of
range.
6. Lift main top from range.
7. Reverse procedure for installation.
Jet Holder Removal
Condition Requirements:
Main Top Removed
Gas Shut Off
Gas leak hazard.
To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer’s
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove screw and top support from range to access
fl
ex tubing.
2. Remove
fl
ex tubing from jet holder.
3. Remove two screws and jet holder from top support.
4. Reverse procedure for installation.
5. Perform gas leak test.