Disassembly
©2010 Viking Preferred Service
35
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Bake/Broil Gas Shutoff Valve Removal
Condition Requirements:
Control Panel Assembly Removed
Gas Shut Off
Gas leak hazard.
To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer’s
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove two of the screws that secure manifold
assembly to range.
2. Pull to remove spark module from burner valve.
3. Remove tubing from back of shutoff valve.
4. Remove screw and shutoff valve from manifold
assembly.
5. Reverse procedure for installation.
6. Perform gas leak test.
IRIS Module Removal
Condition Requirements:
Control Components Accessed
1. Disconnect connectors from module.
2. Pull to remove module from burner valve.
3. Reverse procedure for installation.
Char-Grill Burner and Igniter Removal
(VGSC536-4Q, VGSC548-6Q, & VGSC548-4GQ)
Condition Requirements:
Grill, Plate, and Drip Pans Removed
1. Disconnect wire from igniter.
2. Remove two screws and igniter from burner.
3. Remove two screws and burner from range.
4. Reverse procedure for installation.