background image

Disassembly

24

©2010 Viking Preferred Service

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test 
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service. 
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Oven Light Switch Removal

Condition Requirements:

Control Components Accessed
1.  Mark and disconnect two connectors from light 

switch.

2.  Remove screws and oven light switch from control 

panel.

3.  Reverse procedure for installation.

Door Switch Removal

Condition Requirements:

Control Components Accessed
1.  Remove two screws and door switch from range.
2.  Mark and disconnect two connectors from door 

switch.

3.  Reverse procedure for installation.

Oven Light Bulb Removal

Condition Requirements:

Door Lowered

DO NOT touch bulb with bare hands. Clean off any 
signs of oil from the bulb and handle with a soft cloth.

1.  Unsnap glass light cover using a screwdriver in the 

access groove.

2.  Firmly grasp light bulb and pull out.
3.  Replace with halogen bulb using volt and wattage 

requirements listed on glass cover.

4.  Replace the light cover by snapping glass cover onto 

metal box.

1

2

3

4

Содержание DCCG130

Страница 1: ...e used by qualified appliance technicians only Viking does not assume any responsibility for property damage or personal injury for improper service procedures done by an unqualified person This Base...

Страница 2: ...Door Handle Removal 19 Inner Door Glass Removal 19 Door Hinge Removal 20 Bake Burner Igniter Removal 20 Bake Burner Removal 20 Bake Burner Orifice Removal 20 Broil Burner Igniter Removal 20 Convectio...

Страница 3: ...and others All safety messages will be preceded by the safety alert symbol and the word DANGER WARNING or CAUTION These words mean IMMEDIATE HAZARDS WHICH WILL RESULT IN SEVERE PERSONAL INJURY OR DEA...

Страница 4: ...oduct for any reason alteration outdoor use improper installation improper operation or repair or service of the product by anyone other than an authorized Viking Range Corporation service agency or r...

Страница 5: ...er the base Serial Number 011810C0000000001 Model Number Day Month Year of Manufacture Serial Number D D Designer C C G 1 3 0 D Dual Fuel G Gas 30 30 Wide 1 Series C Custom S Self Cleaning C Convectio...

Страница 6: ...3 wire cord with grounded 3 prong plug attached to unit Maximum amp usage 0 74 amps Surface burner rating Natural gas LP Left front Left rear Right rear Right front Natural Gas LP Propane 16 000 BTU...

Страница 7: ...rom blowing over burners NEVER leave any items on the rangetop The hot air from the vent may ignite flammable items and may increase pressure in closed containers which may cause them to burst Many ae...

Страница 8: ...o cool Other potentially hot surfaces include rangetop areas facing the rangetop oven vent surfaces near the vent opening oven door areas around the oven door and oven window The misuse of oven doors...

Страница 9: ...pe cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation since service pressure may fluctuate with local demand External regulators are not req...

Страница 10: ...or all your casserole dishes as well as easy cleanup The 1500 F closed door infrared broiler allows intense heat to sear delicate cuts of meat providing that restaurant taste Two lights illuminate the...

Страница 11: ...very 4 seconds Control fault Cycle power and retry If fault remains replace DSI 3 flashes every 4 seconds Ignition lockout Control has attempted to ignite but no flame detected after allowing time and...

Страница 12: ...ts and surface burner igniters operate Open or shorted RTD cycle light flashing Replace RTD Open oven control Replace oven control Open direct spark module Replace direct spark module Defective oven w...

Страница 13: ...inoperable bake broil convection fan and surface burner igniters operate Open oven bulbs Replace oven bulbs Open light switch Replace light switch Open door light switch Replace door light switch Def...

Страница 14: ...120 VAC present on oven control thermostat L1 to N 120 VAC present on DSI module A to N Turn oven control knob to 350 120 VAC present on thermostat violet to N Turn oven control knob to 350 120 VAC pr...

Страница 15: ...VAC present on oven control thermostat L1 to N 120 VAC present on DSI module A to N Turn oven control knob to broil 120 VAC present on thermostat blue to N Turn oven control knob to broil 120 VAC pres...

Страница 16: ...cord black disconnect black Cycle Light 120 VAC Open neon light Cycle light terminals black to white Oven Light Switch OFF Door Closed 120 VAC Open Oven light switch terminals black to red Oven Light...

Страница 17: ...120 VAC is present in step 5 and the black igniter wire has continuity replace the spark module RTD Characteristics Proper diagnostics of the RTD Resistance Temperature Detector will eliminate unneces...

Страница 18: ...oor Assembly Adjustment Screw 5 Reverse procedure for installation Note If the door needs to be adjusted loosen hinge trim screws Adjust the screws located between the door and kick plate using a 5 32...

Страница 19: ...dle 3 Reverse procedure for installation Inner Door Glass Removal Condition Requirements Outer Door Panel Assembly Removed 1 Place the inner door panel assembly on a protected surface 2 Remove screws...

Страница 20: ...emoved 1 Remove screws and lift kick plate from keyhole screws 2 Lift to remove oven cavity bottom panel from range 3 Disconnect wire from igniter 4 Remove screw and igniter from bake burner 5 Reverse...

Страница 21: ...bottom panel from range 2 Remove screws and fan cover from oven cavity 3 Remove four outer screws and convection motor assembly from oven cavity 4 Mark and disconnect two connectors from convection m...

Страница 22: ...l injury or death leak testing of the appliance must be conducted according to the manufacturer s instructions Before placing appliance in operation always check for gas leaks with soapy water solutio...

Страница 23: ...cedure for installation Control Panel Assembly Removal Condition Requirements Control Components Accessed 1 Mark and disconnect all connectors to remove control panel from range 2 Reverse procedure fo...

Страница 24: ...oven light switch from control panel 3 Reverse procedure for installation Door Switch Removal Condition Requirements Control Components Accessed 1 Remove two screws and door switch from range 2 Mark a...

Страница 25: ...Module Removal Condition Requirements Control Components Accessed 1 Disconnect connectors from module 2 Pull to remove module from burner valve 3 Reverse procedure for installation Burner Base Assemb...

Страница 26: ...emove two of the screws that secure manifold assembly to range 2 Pull to remove spark module from burner valve 3 Remove flex tubing from back of burner valve 4 Remove screw and burner valve from manif...

Страница 27: ...emoval Condition Requirements Door Assembly Removed Back Panel Removed 1 Remove nut from broil burner and gas tubing 2 Remove screws that secure igniter to oven cavity 3 Remove screws and rear broil b...

Страница 28: ...gh the oven cavity cut the two wires and splice in the replacement RTD with the use of two 2 ceramic wire nut connectors 1 Disconnect RTD Molex connector in burner box area 2 Remove any wire ties as r...

Страница 29: ...soapy water solution DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS 1 Remove screws and bracket from range 2 Remove nut and gas tubing from bracket 3 Mark and disconnect wires from solenoid valve 4...

Страница 30: ...lly open and closes at 150 F 1 Mark and disconnect connectors from temperature switch 2 Remove screws and temperature switch from side of range 3 Reverse procedure for installation Terminal Block Remo...

Страница 31: ...screws from each burner base assembly 4 Lift each burner base assembly up to remove from range Note Keep igniter wires attached to each burner base assembly during removal 5 Remove screws and side tr...

Страница 32: ...equirements Main Top Removed Gas Supply Disconnected Gas leak hazard To avoid risk of personal injury or death leak testing of the appliance must be conducted according to the manufacturer s instructi...

Страница 33: ...Wiring Diagrams 2010 Viking Preferred Service 33 Electronic Thermostat DSI System Oven Control Thermostat and DSI Module System...

Страница 34: ...1 S1 VALVE 1 SC COMMON S2 VALVE2 BAKE L1 BROIL YELLOW YELLOW BROWN BLACK P6 J2 P4 P1 N L1 BLACK RED RED RED WHITE WHITE WHITE WHITE WHITE CONVECTION SWITCH SWITCH INDICATOR CONVECTION FAN MOTOR M SIN...

Страница 35: ...2010 Viking Preferred Service 35...

Страница 36: ...36 2010 Viking Preferred Service...

Отзывы: