Disassembly
©2010 Viking Preferred Service
21
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Convection Fan Assembly Removal
Condition Requirements:
Door Assembly Removed
Rack Supports Removed
1. Lift to remove oven cavity bottom panel from range.
2. Remove screws and fan cover from oven cavity.
3. Remove four outer screws and convection motor
assembly from oven cavity.
4. Mark and disconnect two connectors from convection
motor assembly.
5. Remove left hand nut and fan blade from convection
fan.
6. Reverse procedure for installation.
DSI Module Accessed
Condition Requirements:
Door Assembly Removed
1. Remove screws and lift kick plate from keyhole
screws.
2. Remove keyhole screws and brace from range.
3. Remove screws and component tray from range to
access DSI module.
Note:
During installation ensure that the tabs on the
component tray slide into slots on the range for
support.
4. Reverse procedure for installation.