Disassembly
©2010 Viking Preferred Service
27
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Island Trim Removal
Condition Requirements:
Rear of Range Accessed
1. Remove screws and island trim from range.
2. Reverse procedure for installation.
Back Panel Removal
Condition Requirements:
Island Trim Removed
1. Remove screws and back panel from range.
2. Reverse procedure for installation.
Broil Burner Removal
Condition Requirements:
Door Assembly Removed
Back Panel Removed
1. Remove nut from broil burner and gas tubing.
2. Remove screws that secure igniter to oven cavity.
3. Remove screws and rear broil burner bracket from
oven cavity.
4. Remove screws and front broil burner bracket from
oven cavity.
5. Pull broil burner from range.
6. Reverse procedure for installation.
Cooling Fan Removal
Condition Requirements:
Back Panel Removed
Note:
The cooling fan is controlled by the cooling fan
temperature switch which is N.O. (normally
open) and closes at 150°F.
1. Pull two connectors through hole in side of range.
2. Mark and disconnect connectors from cooling fan.
3. Remove screws and cooling fan from fan bracket.
Note:
Each screw has a spacer between the cooling
fan and the range. Ensure each spacer is
positioned properly during installation.
4. Reverse procedure for installation.
Содержание DCCG130
Страница 35: ...2010 Viking Preferred Service 35...
Страница 36: ...36 2010 Viking Preferred Service...