Disassembly
©2010 Viking Preferred Service
31
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Main Top Removal
Condition Requirements:
Control Panel Assembly Removed
Island Trim Removed
1. Remove grates, burner caps, and burner heads from
each burner base assembly.
2. Mark and disconnect ignition wire from each IRIS
module.
3. Remove screws from each burner base assembly.
4. Lift each burner base assembly up to remove from
range.
Note:
Keep igniter wires attached to each burner base
assembly during removal.
5. Remove screws and side trim from each side of
range.
6. Lift main top from range.
7. Reverse procedure for installation.
Jet Holder Removal
Condition Requirements:
Main Top Removed
Gas Shut Off
Gas leak hazard.
To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer’s
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove flex tubing from jet holder.
2. Remove screws and jet holder from range.
3. Reverse procedure for installation.
4. Perform gas leak test.