Side Light Housing Removal
Condition Requirements:
Door Assembly Removed
Rack Supports Removed
1. Remove screws and lift kick plate from keyhole
screws.
2. Disconnect connector for side light housing.
3. Remove screw and side light housing from oven liner.
4. Reverse procedure for installation.
IRIS Module Removal
Condition Requirements:
Control Components Accessed
1. Disconnect connectors from module.
2. Pull to remove module from burner valve.
3. Reverse procedure for installation.
Burner Base Assembly Removal
Condition Requirements:
None
1. Remove grates, burner cap, and burner head from
burner base assembly.
2. Remove two screws and lift burner base assembly
from range.
3. Disconnect wire from burner base assembly.
4. Reverse procedure for installation.
Orifice Removal
Condition Requirements:
Burner Base Removed
Note:
Use a socket with a small ball of tape or
something tacky to keep the orifice during
removal.
1. Remove orifice from jet holder.
Note:
Use a socket with a small ball of tape or
something tacky to keep the orifice during
installation. Ensure that the tacky substance
does not block the hole of the orifice.
2. Reverse procedure for installation.