Page 1: ...e r a t i o n M a n u a l RN8910GE RN8910GEC Gas Range Electric Static Convection Ovens Date Purchased Serial Number Dealer Service Provider 232781 9 For use in GB IE RNL8910GE RNL8910GEC RNB8910GE R...

Page 2: ...res tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 145...

Page 3: ...quirements Electrical Connection Dimensions 7 Installation 8 Installation Requirements Unpacking Location Clearances Assembly Fitting Rear Rollers Gas Connection Electrical Connection Commissioning Op...

Page 4: ...FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED...

Page 5: ...Open Burner Options F With Flame Failure Protection PF With Pilot and Flame Failure Protection General A heavy duty general purpose gas range created for compact modular kitchens It is available on in...

Page 6: ...Open Burner each Heat Input nett Nominal 6 5 kW 6 5 kW Reduced 1 75 kW 1 75 kW Gas Rate nett Nominal 0 69 m3 hr 0 51 kg hr Reduced 0 19 m3 hr 0 14 kg hr Supply Pressure 20 mbar 37 mbar Burner Operatin...

Page 7: ...ion Gas supply connection point is located at rear of appliance approximately 130mm from right hand side 32mm from rear and 655mm from floor and is reached from beneath appliance Refer to Dimensions s...

Page 8: ...as per AS NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g HO5 RN F Type Branch supply line shall be individually overload protected to correct current rating and supply chord shall be protected against...

Page 9: ...7 Dimensions RN L 8910GE GEC Refer to Page 8 for Cook Top Options...

Page 10: ...manufacturer s specifications shown in this section will void the warranty Components having adjustments protected e g paint sealed by manufacturer are only to be adjusted by an authorised service ag...

Page 11: ...for fitting instructions Optional Accessories Refer to Replacement Parts List Plinth Kit For installation details refer to instructions supplied with each kit Fitting Rear Rollers 1 Raise appliance fr...

Page 12: ...supply line as close to appliance as possible NOTE Gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as shown in Gas Conversion Section in this manual Ens...

Page 13: ...pply Requirements Table in Specifications Section 5 Connect neutral and earth conductors to neutral stud and earth stud respectively 6 For all connections ensure conductors are secure and appropriatel...

Page 14: ...eration Check the Oven Fan Operation GEC Models only b Ensure operator has been instructed in the areas of correct lighting operation and shutdown procedure for appliance 2 This manual must be kept by...

Page 15: ...Indicator Lamps Amber for Top Bottom Elements Power Indicator Lamp green Open Burner Option OFF Position HIGH Flame LOW Flame Rear Burner Front Burner Indicators located above the Gas Control Knobs O...

Page 16: ...s These hobs are fitted with individual standing pilots for each open burner which allows main burners to be turned ON OFF without having to manually re light burner each time that it is turned ON as...

Page 17: ...Preheat Preheat oven by selecting desired temperature and turning oven top heat control to a maximum of 2 When desired temperature is reached Amber Neons will go out 4 Cooking When desired temperature...

Page 18: ...erial has been completely removed after each cleaning To keep your Cooktop clean and operating at peak efficiency follow the procedures shown overleaf Always turn off the gas electrical supply before...

Page 19: ...pty spill tray and wash with warm soapy water 5 Dry all components thoroughly and re assemble Oven Interior Cleaning 1 Do not use wire brushes steel wool or other abrasive materials to clean oven inte...

Page 20: ...ermocouple connection to gas control loose or faulty Thermocouple faulty Electromagnet in rear of gas control unit is faulty Hold knob in for at least 20 seconds following ignition of pilot Clean or r...

Page 21: ...Wiring Schematic 19 RN8910GE Wiring Schematic...

Page 22: ...Wiring Schematic 20 RN8910GE Wiring Diagram...

Page 23: ...Wiring Schematic 21 RN8910GEC Wiring Schematic...

Page 24: ...Wiring Schematic 22 RN8910GEC Wiring Diagram...

Page 25: ...nds burner caps and burner bodies and the pot stand supports 2 Remove injectors and replace with correct size injectors as shown in Gas Specifications Tables at end of this section 3 Refit the pot sta...

Page 26: ...Re adjust regulator if required 5 Screw cap nut back onto regulator Gas Type Identification Label On completion of gas conversion replace gas type identification label located at Rear of appliance ab...

Page 27: ...as Propane Open Burner Main Burner Injectors 2 45mm 1 50mm Pilot Burner PF Option Only 0 30 0 20 Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 6 kPa Gas Regulator Ca...

Page 28: ...adjustable gas regulator supplied Refer to information in this section for further details Natural Gas Town Gas Open Burner Main Burner 2 45mm 4 50mm Pilot Burner PF Option Only 0 30 0 60 Supply Press...

Page 29: ...Failure 227967 Knob Open Burner 228167 Thermocouple Front 228166 Thermocouple Rear Oven 228691 Oven Top Element 1 75kW 750 Ovens 228690 Oven Bottom Element 3 75kW 750 Ovens 228082 Oven Top Element 2k...

Page 30: ...Legs 229674 Rear Roller Assy Accessories 228800 900mm Plinth Kit Gas Regulators Gas Conversion Kits Gas Type Gas Regulators Part No Description Nat Gas LPG Butane 228531 BSP F F Convertible Town Gas 2...

Page 31: ......