Gas connection
A
Gas connection
Notes regarding operation with
LPG
We recommend the installation of an
external safety solenoid valve when
installing the compact boiler in rooms
below ground level.
1.
Carry out a leak/soundness test.
!
Please note
Excessive test pressure
may damage the compact
boiler and the gas valve.
Max. test pressure 150
mbar. Where higher pres-
sure is required for sound-
ness tests, separate the
compact boiler and the gas
valves from the gas supply
pipe (undo the fitting).
2.
Vent the gas supply pipe.
Conversion to other gas
types:
See "Commissioning, inspec-
tion, maintenance"
Electrical connections
Information regarding the connection of accessories
For details of accessories, also observe their separate installation
instructions provided.
Fitting the connections
(cont.)
17
Installation sequence
5592
883
GB
Installation