Checking the plate-type heat exchanger
1.
Remove cover panel
A
.
2.
Shut off the heating water side of
the compact boiler.
3.
Close the on-site shut-off valve.
4.
Drain the boiler on the DHW side
via drain valve
B
.
5.
Drain the system on the heating
water side via drain valve
C
.
6.
Undo fittings
D
.
7.
Pull the locking bracket from plug-
in connectors
E
and pull the con-
nections on the heating water
side.