Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
20 minutes
F6:0
*
6
*
6
In the "DHW only"
operating mode, the
internal circulation
pump is permanently
OFF
F6:1
to
F6:24
In the "DHW only" operat-
ing mode, the internal cir-
culation pump will be
started 1 to 24 times per
day for 10 minutes
respectively.
F6:25
In the "DHW only" operat-
ing mode, the internal cir-
culation pump is
permanently ON
F7:0
*
6
*
6
Internal circulation
pump is permanently
OFF in operating mode
"Standby mode"
F7:1
to
F7:24
In "Standby mode", the
internal circulation pump
will be started 1 to 24
times per day for
10 minutes respectively.
F7:25
*
6
*
6
Internal circulation
pump is permanently ON
in operating mode
"Standby mode"
Resetting the coding to the as delivered condition
1.
Press
L
and
G
simultaneously
for approx. 2 seconds.
2.
Press
e
.
"Basic setting? Yes" with
d
.
With
a
or
b
, you can select
"Basic setting? Yes" or "Basic set-
ting? No".
Code 2
(cont.)
61
Coding
56
92
548
GB
*6
Only for constant temperature control units.
Содержание VITODENS 333
Страница 114: ...Parts lists cont 114 Parts lists 5692 548 GB ...
Страница 115: ...Parts lists cont 115 Parts lists 5692 548 GB ...
Страница 116: ...Parts lists cont 116 Parts lists 5692 548 GB ...
Страница 117: ...Parts lists cont 117 Parts lists 5692 548 GB ...
Страница 118: ...Parts lists cont 118 Parts lists 5692 548 GB ...
Страница 119: ...Parts lists cont 119 Parts lists 5692 548 GB ...
Страница 131: ...131 5692 548 GB ...