Checking all gas equipment for soundness at operating pres-
sure
Danger
Escaping gas leads to a risk of
explosion.
Check gas equipment for
soundness.
Checking the ionisation current
A
Adaptor line (available as acces-
sory)
1.
Pull the line off and connect test
equipment (adaptor line available
as accessory).
2.
Set the upper rated output.
Constant temperature control unit:
&
Press
K
and
d
simultaneously
for at least 2 seconds.
&
With
a
/
b
in the display, select
2.
Weather-compensated control unit:
&
Press
K
and
d
simultaneously
for at least 2 seconds.
&
With
a
/
b
in the display, select
Full load.
Note
The minimum ionisation current
should be at least 4 µA as soon as
the flame is established (approx. 2-
3 seconds after opening the gas
combination valve).
3.
If the ionisation current is < 4 µA
&
Check the electrode gap, see
page 21.
&
Check the control unit power sup-
ply.
Further details regarding the individual steps
(cont.)
26
Initial start-up, inspection, maintenance
56
92
548
GB
Содержание VITODENS 333
Страница 114: ...Parts lists cont 114 Parts lists 5692 548 GB ...
Страница 115: ...Parts lists cont 115 Parts lists 5692 548 GB ...
Страница 116: ...Parts lists cont 116 Parts lists 5692 548 GB ...
Страница 117: ...Parts lists cont 117 Parts lists 5692 548 GB ...
Страница 118: ...Parts lists cont 118 Parts lists 5692 548 GB ...
Страница 119: ...Parts lists cont 119 Parts lists 5692 548 GB ...
Страница 131: ...131 5692 548 GB ...