Rated voltage:
230 V~
Rated frequency:
50 Hz
Rated current :
6.3 A~
Safety class:
I
Protection level:
IP X 4 D to
EN 60529
Permissible ambient temperature
&
in operation:
0 to +40 °C
&
during storage
and transport:
-20 to +65 °C
Electronic tempera-
ture limiter setting:
82 °C
Temperature limiter
setting:
100 °C (fixed)
Mains fuse:
Max. 16 A
Power consumption
&
Circulation pump:
Max. 115 W
&
Burner:
Max. 60 W
&
Control unit:
Max. 10 VA
Gas fired boiler, category II
2ELL3P
Rated output T
V
/T
R
50/30 °C
kW
6.6 to 26
Rated output range
kW
6.3 to 24.7
Connection values
*
1
Relative to the max. load
with
with H
uB
natural gas E
9.45 kWh/m
3
34.02 MJ/m
3
m
3
/h
2.65
natural gas LL
8.13 kWh/m
3
29.25 MJ/m
3
m
3
/h
3.08
LPG
12.79 kWh/m
3
46.04 MJ/m
3
m
3
/h
1.94
Product ID
_
-0085 BO
0338
Product characteristics (to EnEV [Germany])
Rated output range
kW
6.6 to 26
Efficiency
µ for
&
100 % of rated output
%
96.3
&
30 % of rated output
%
107.4
Standby loss
q
B,70
*
2
%
0.7
Power consumption
*
2
for
&
100 % of rated output
W
207
&
30 % of rated output
W
69
Specification
126
Specification
56
92
548
GB
*1
The supply values are only for reference (e.g. in the gas contract application) or to esti-
mate the supplementary volumetric settings. Because of factory settings, the gas pres-
sure must not be altered from these values. Reference: 15 °C, 1013 mbar.
*2
Max. limit to EnEV
Содержание VITODENS 333
Страница 114: ...Parts lists cont 114 Parts lists 5692 548 GB ...
Страница 115: ...Parts lists cont 115 Parts lists 5692 548 GB ...
Страница 116: ...Parts lists cont 116 Parts lists 5692 548 GB ...
Страница 117: ...Parts lists cont 117 Parts lists 5692 548 GB ...
Страница 118: ...Parts lists cont 118 Parts lists 5692 548 GB ...
Страница 119: ...Parts lists cont 119 Parts lists 5692 548 GB ...
Страница 131: ...131 5692 548 GB ...