5.
Record the gas type in the commis-
sioning/service report on page
120.
Checking static and supply pressure
Danger
Higher CO emissions can lead to poisoning.
Measure the CO value before and after any work on gas equipment to
prevent any health hazards and to ensure the perfect operational condi-
tion of the system.
Operation with LPG
Flush the LPG tank twice during commissioning/replacement. Thoroughly vent
the tank and gas lines after flushing.
1.
Close the gas shut-off valve.
2.
Release the screw inside test nip-
ple PE
A
on the gas combination
valve, but do not remove, and con-
nect the pressure gauge.
3.
Open the gas shut-off valve.
4.
Check the static pressure; it should
be a max. of 57.5 mbar. Record the
actual value in the service report.
5.
Start up boiler.
Note
During commissioning, the boiler
can enter a fault state because of
airlocks in the gas pipe. After
approx. 5 seconds, press
E
to
reset the burner.
Further details regarding the individual steps
(cont.)
13
Initial start-up, inspection, maintenance
56
92
548
GB
Содержание VITODENS 333
Страница 114: ...Parts lists cont 114 Parts lists 5692 548 GB ...
Страница 115: ...Parts lists cont 115 Parts lists 5692 548 GB ...
Страница 116: ...Parts lists cont 116 Parts lists 5692 548 GB ...
Страница 117: ...Parts lists cont 117 Parts lists 5692 548 GB ...
Страница 118: ...Parts lists cont 118 Parts lists 5692 548 GB ...
Страница 119: ...Parts lists cont 119 Parts lists 5692 548 GB ...
Страница 131: ...131 5692 548 GB ...