Checking O-rings:
1.
Pull off the electrical plug
A
.
2.
Remove sensor
B
by pulling it
upwards.
3.
Ensure that both O-rings
C
are
properly inserted into aperture
adaptor retainers
D
.
4.
Insert the sensor with connection
nipples into the gas combination
valve adaptor and push in until it
clicks into place.
5.
Reconnect the electrical plug-in
connector on the sensor.
Repairs
(cont.)
91
Troubleshooting