Codes
Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
System design
00 :2
System design 1:
1 heating circuit without
mixer A1, with DHW
heating
00 :4
System design 2, 5:
1 mixer circuit M2, with
DHW heating
00 :6
System design 3, 4:
1 heating circuit without
mixer A1, 1 mixer circuit
M2 with DHW heating
Boiler/burner
06:...
Maximum limit of the
boiler water tempera-
ture, defaulted by the
boiler coding card
06:20
to
06:127
Maximum limit of the boi-
ler water temperature
within the ranges
defaulted by the boiler
1E:0
Operation with natural
gas
1E:1
Operation with LPG
21:0
No maintenance indica-
tion
Burner
21:1
to
21:100
The number of hours run
before the burner should
be serviced is adjustable
from 100 to 10000 hours
(each step represents
100 hours)
23:0
No time interval for bur-
ner maintenance
23:1
to
23:24
Time interval adjustable
from 1 to 24 months
24:0
No "Maintenance" dis-
play
24:1
"Maintenance" display
(the address is automati-
cally set and must be
manually reset after
maintenance has been
completed)
Code 2
(cont.)
43
Coding
56
92
548
GB
Содержание VITODENS 333
Страница 114: ...Parts lists cont 114 Parts lists 5692 548 GB ...
Страница 115: ...Parts lists cont 115 Parts lists 5692 548 GB ...
Страница 116: ...Parts lists cont 116 Parts lists 5692 548 GB ...
Страница 117: ...Parts lists cont 117 Parts lists 5692 548 GB ...
Страница 118: ...Parts lists cont 118 Parts lists 5692 548 GB ...
Страница 119: ...Parts lists cont 119 Parts lists 5692 548 GB ...
Страница 131: ...131 5692 548 GB ...