64
Row (brief
scan)
Field
1
2
3
4
5
6
Heating circuit A1 (without
mixer)
Heating circuit M2 (with
mixer)
Heating circuit M3 (with mix-
er)
9:
Remote con-
trol
0: Without
1: Vitotrol
200-A/
200-RF
2: Vitotrol
300-A/
300-RF
or
Vitocomfort
Software ver-
sion
Remote con-
trol
0: No remote
control
Remote con-
trol
0: Without
1: Vitotrol
200-A/
200-RF
2: Vitotrol
300-A/
300-RF
or
Vitocomfort
Software ver-
sion
Remote con-
trol
0: No remote
control
Remote con-
trol
0: Without
1: Vitotrol
200-A/
200-RF
2: Vitotrol
300-A/
300-RF
or
Vitocomfort
Software version
Remote control
0: No remote
control
10:
0
0
0
0
0
0
11
0
0
Software ver-
sion
Mixer exten-
sion, heating
circuit M2
0: No mixer
extension
0
Software ver-
sion
Mixer exten-
sion, heating
circuit M3
0: No mixer
extension
0
Testing outputs (relay test)
1.
Press
OK
and
å
simultaneously for approx. 4 s.
2. "Actuator test"
The following relay outputs can be controlled subject to the system equipment level:
Display
Explanation
All actuators
OFF
All actuators are off
Base load
ON
Burner operates at lower heating output; internal pump starts
Full load
ON
Burner operates at upper heating output; internal pump starts
Valve
Heating
Diverter valve set to heating mode
Valve
Center
Diverter valve in central position (filling/draining)
Valve
DHW
Diverter valve set to DHW heating
Htg circ pump HC2
ON
Output for heating circuit pump enabled (extension heating circuit with
mixer)
Mixing valve HC2
Open
Output for "Mixer open" enabled (extension heating circuit with mixer)
Mixing valve HC2
Close
Output for "Mixer close" enabled (extension heating circuit with mixer)
Htg circ pump HC3
ON
Output for heating circuit pump enabled (extension heating circuit with
mixer)
Mixing valve HC3
Open
Output for "Mixer open" enabled (extension heating circuit with mixer)
Mixing valve HC3
Close
Output for "Mixer close" enabled (extension heating circuit with mixer)
Outp. int. exten. H3
ON
Output
sÖ
(internal pump) at internal extension enabled
AM1 output 1
ON
Output A1 at AM1 extension enabled
AM1 output 2
ON
Output A2 at AM1 extension enabled
EA1 output 1
ON
Contact P - S at plug
aBJ
of EA1 extension closed
Solar circuit pump
ON
Solar circuit pump output
sF
on solar control module SM1 enabled
Solar circ pmp min
ON
Solar circuit pump output on solar control module SM1 switched to
minimum speed
Diagnosis and service scans
Diagnosis
(cont.)
5686 293 GB
Diagnosis
Содержание J3HA
Страница 10: ...10 2x 1 2 4 3 Fig 2 Installation sequence Mounting the boiler and making connections 5686 293 GB Installation ...
Страница 21: ...21 2 3 2x 1 Fig 14 Installation sequence Fitting the front panel 5686 293 GB Installation ...
Страница 78: ...78 Troubleshooting Maintenance cont 5686 293 GB Diagnosis ...
Страница 90: ...90 0004 0006 0005 0003 0001 0002 Fig 51 Parts lists Miscellaneous assembly 5686 293 GB Components ...
Страница 114: ...114 5686 293 GB ...
Страница 115: ...115 5686 293 GB ...