background image

a  snapshot,  and view where files are stored.  In video  viewing, the 
view screen ratio can be selected from the Video size drop-down list 
(Fit, Full, 1x, 1/2x, 1/4x). Fit mode allows the video to be the size of 
the window without changing the aspect ratio; Full mode spreads 
over the entire window and the aspect ratio changes with the size of 
the window; 1X maintains the full resolution of the video and 1/2X 
and 1/4X reduces the resolution by ½ or ¼, respectively. Users can 
also select the Play mode as “Live” or “Fluid” per the scene; Fluid 
will produce a smoother image.   
 
Click the button 

  can take a snapshot of the current image. Click 

the button 

  to access the saving path of the snapshot. The default 

path is: C:\VideoPlayerAX\Picture. 
 
Surveyor MKII HD series domes support local PC recording. Click 
the recording button 

  to start the recording, and the button turns 

to 

. Click the button 

  to stop the recording. When recording 

to a local PC, prompt characters of “REC” will be displayed on the 
video interface. Clicking the button 

  can access the record saving 

path. The default saving path is: C:\VideoPlayerAX\ Video. (Saving 
paths for snapshot and record can be set in the Audio video settings 
interface. Refer to the section 3.5.5 for details.) 
 
Expand the option "Function switch"; the buttons 

  represents 

that the audio input and output are closed. Clicking the buttons can 
switch on the functions. Buttons 

  represent that the functions 

of motion detection and privacy mask are enabled. Click the buttons 
to turn them into 

  to disable the function.   

 

Note: 

The motion detection and privacy mask settings can only be 

set in the Live view settings interface when the motion detection and 
privacy mask functions are enabled in the  Audio video  interface,. 
Refer to the sections 3.5.3 and 3.5.4 for details.   
 
In the Live view interface, users can perform PTZ control, call up 
PTZ functions and conduct image PTZ operations. Refer to Chapter 
IV for details.   
 
Click the “Setting” button at the top of the screen to enter the System 
Settings interface. 

Figure 3-3 System settings interface 

 

From the left navigation bar, the user  can check the system 
information, including time settings and advanced settings, network 

settings, camera settings, video and audio  settings, PTZ functions, 
schedules (time  functions), alarm settings, record  settings,  user 
management  (add/delete user, change password), and view  the 
system log operations.   
 

3.2 System 

Click  “System”  in  the left navigation bar and the  system  setting 
interface is shown as in Figure 3-3. The system interface includes 3 
options: System, Time, and Advanced.   
 

3.2.1 System Settings 

The initial interface for system setting is the “System”  interface. 
From  the  interface, users can see the setting information  of the 
system,  including: basic information, network settings, alarm 
settings, NTP settings, H.264 video settings, MJPEG video settings, 
and other information (including temperature, humidity).   

3.2.2 Time Settings 

 

Figure 3-4 Time setting interface 

 

Time zone settings 

Time zone: select the proper time zone in the drop-down list. There 
are 33 time zones available.   
If daylight saving time is used in the location, users can enable the 
option “Daylight saving time”. 
Click the “Save” button to finish the setting. 

 
Time format settings 

Select the time format from the drop-down as MMDDYYY, 
DDMMYYYY or YYYYMMDD. Also select the time format from 
24 hour or 12 hour   
 

NTP set   

Set NTP server IP, Sync time interval parameters and to turn sync on 
(enable) or off.   
 
After the settings, click the “Save” button to finish the setting. 
 

Содержание Surveyor MKII Series XX282-40-01

Страница 1: ...d in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc Tel 631 952 2288 Fax 631 951 2288 Toll Free 8...

Страница 2: ...emarks that may appear belong to their respective proprietors FCC Warning The Surveyor MKII HD Network Domes comply with the FCC rules Operation is subject to the following two conditions This device...

Страница 3: ...from ground and entrance Refer to qualified personnel for all service matters Save product packaging to ensure availability of proper shipping containers for future transportation The power supply of...

Страница 4: ...8 3 3 7 IGMP 8 3 3 8 SIP 8 3 3 9 MDA 9 3 3 10 DDNS Setting 9 3 3 11 UPnP Setting 9 3 3 12 IP Filter Setting 9 3 4 Camera Settings 10 3 5 Audio Video 11 3 5 1 Video Settings 11 3 5 2 OSD 11 3 5 3 Moti...

Страница 5: ...og function IP67 environmental rating with built in heater and air cycle system and freeze proof 1 3 Product Specifications Lens Optical Zoom 30X Aperture Focal Length F1 4 F4 6 f 4 4 132 0mm Angle of...

Страница 6: ...Chapter II IE Browser Setting The user must set the IE browser and system before attempting to view the video When setting the IE browser note that the dome supports IE browser versions of Internet Ex...

Страница 7: ...ning the software users should use the default admin username and password The default User is ADMIN uppercase case sensitive Password 1234 Input the correct user name and password and then press OK t...

Страница 8: ...ion and privacy mask functions are enabled in the Audio video interface Refer to the sections 3 5 3 and 3 5 4 for details In the Live view interface users can perform PTZ control call up PTZ functions...

Страница 9: ...ed Note Available only for the admin Factory Settings Surveyor MKII HD series domes provides an online reset function which greatly facilitates reset adjustment Click Maintain current IP so the IP add...

Страница 10: ...e turned On or Off as required 3 3 2 FTP Figure 3 11 FTP settings Surveyor MKII HD series domes support the function of alarm associated FTP image unloading automatically capture images when alarm occ...

Страница 11: ...ethod and enter the user name and password 3 3 6 QoS Figure 3 15 QoS settings Users can set the network service quality in the QoS setting interface There are 4 network Qos modes to be selected 1 Norm...

Страница 12: ...ame System DDNS can enable constant synchronization of the host name and the dynamic IP address Users only need to input the dynamic domain name to connect to a network camera instead of memorizing th...

Страница 13: ...ue light AGC can be set Exposure Parameter settings are shown below Mode Set exposure mode Auto low Auto medium Auto high Auto D N Shutter Exposure Level In Shutter mode set the Level and select from...

Страница 14: ...CBR constant bit rate and Dynamic options With variable bit rate the system can automatically adjust the bandwidth of the images per the complexity of the images In practical use the complexity of the...

Страница 15: ...OFF and then click the button Save 3 5 3 Motion Detection Figure 3 28 Motion detection settings Motion detection function is supported Up to 4 motion zones can be configured If the zone number is alre...

Страница 16: ...t position 7 Press Delete button to delete the selected preset 8 Press Delete all button to delete all the presets 3 6 2 Scan Select Scan tab and the interface is shown as follows Figure 3 32 Scan 1 S...

Страница 17: ...eriod of time In the setting interface users can set return time action No 1 32 preset No 1 4 Auto tours and No 1 4 Scan are options and decide whether to return to the position before powering off 3...

Страница 18: ...ngle normal far vision 3 7 Schedules Click Schedule on the left navigation bar to display the Schedules interface shown below Figure 3 38 Time function In Mode setting the Act mode status and effectiv...

Страница 19: ...e can be set Users can select the alarm period For example if Sunday is checked then on each Sunday the alarm settings will be in effect in the set time if Everyday is selected then the alarm settings...

Страница 20: ...s operators or viewers and change their passwords The user name ADMIN cannot be changed but it is recommended to change the ADMIN password for increased security The system supports up to 8 users The...

Страница 21: ...TZ control tab to expand the PTZ control interface as shown below Figure 4 1 PTZ control interface In the interface users can perform PTZ control iris adjustment focus zoom adjustment and also set the...

Страница 22: ...ere of the selected area with the mouse the target area will be centered on the video display screen Figure 4 4 Dragging the frame with mouse Figure 4 5 Selected area zoom and centered When the option...

Страница 23: ...y interface right click the window and select Snapshot in the popped up menu then the current image can be saved to the local PC For instruction about the snapshot saving path please refer to the sect...

Страница 24: ...V1 0 1511...

Страница 25: ...VICON INDUSTRIES INC For office locations visit the website www vicon security com...

Отзывы: