background image

10 

 
IP address format: xxx.yyy.yyy.zzz/www. 
 
 
Note: For xxx you can select from 1~233 except 127; for yyy you 
can select 0~255; for zzz you can select 1~254 and for www you 
can select 1~24. 
Click the Save button after you add an IP address and the added IP 
address will appear on the IP address list. If you tick the Enable IP 
Filter check box,  you can only access the IP addresses that have 
been added. Prior to enabling IP Filter, you can ensure that there 
are IP addresses to access and you can remember the addressable 
IP. 
On address list in the right side Operate column of the IP address 
list, click the 

  icon to delete and the 

  icon to edit. 

 

3.4 Camera Settings 

Note: 

The dome supports the editing of the camera parameters.  In 

the camera setting interface, users can set 6 groups  (profiles)  of 
parameters, defining each group as a mode. Additionally,  the set 
mode can also be changed. In the Schedule Time Function interface, 
users can call up the different modes and set them individually. Refer 
to the section 3.7. 

 

Click “Camera” tab to display the interface shown as below. The 
configuration items include Zoom, Iris, Focus, White Balance, 
Exposure, Day/Night, and Special function; a Restore default 
settings button is provided to return all settings back to factory 
defaults. 

Figure 3-25 Camera settings 

 

Zoom: 

Set the zoom speed (Fast or Slow) and perform zoom in/out 

operations.   

Iris:

 Set iris mode from the dropdown list of M/A (manual priority), 

Auto, and Manual. Iris value and Iris average are settable when Auto 
mode (M/A or Manual) is not selected. 

Focus: 

The following parameters can be set; 

 

Mode: 

M/A (manual priority), Auto and Manual. 

 

Focus limit: 

10cm, 30cm, 1m, and 3m. 

Click Restore default settings to undo any settings and return the 
camera to factory default settings 

White Balance 

Mode:  Select Auto, Manual, Sodium, or  Mercury. When the white 
balance is set as “Manual”, the R-gain (red light AGC) and B-gain 
(blue light AGC) can be set. 

Exposure 

Parameter settings are shown below: 

 

Mode: Set exposure mode, Auto (low)/Auto (medium)/Auto 
high)/Auto (D/N)/Shutter/Exposure.   

 

Level: In Shutter mode, set the Level and select from 
1/2s~1/30000s (16) levels adjustable

in Exposure mode, set iris 

level and select from F3.2~F9.1 (4) levels adjustable. 

 

Backlight: On, Off. When the BLC is turned on, the level of BLC 
can be set. 

 

DSS  (Digital Slow Shutter): The digital slow shutter slows the 
picture frame rate and enhances the camera’s sensitivity in poorly 
lit environments. When Exposure mode is set to Auto mode, DSS 
is settable in 1/60~1/2 (6) levels.   

 

WDR mode: Off, WDR, AD WDR. 

 

Image  Stabilization (EIS): On, Off. When set to On, select 
frequency. 

 

Day/Night 

 

The BWC mode and BWC sens will change according to the 
Exposure mode  setting. When the Exposure mode is selected as 
“Shutter” or “Exposure”, the BWC mode is displayed as “Manual”, 
and then the BWC settings can be set in the “Manual” BWC mode 
list. 

 

Manual BWC mode: Select Color or  B/W mode options. Color: 
the video is in color; B/W: the video is in black-and-white. 

 

Note: 

In Auto Exposure modes, the exposure is automatic, but the 

BWC switch can be controlled manually.   
 

Special Functions: 

 

Mirror mode: Off, H-mirror, V-mirror, HV-mirror. 

 

Freeze: On, Off, Freeze Preset (Pst). 

 

Sharpness: Auto, Manual. In Auto mode, the sharpness will auto 
adjust  as per the video; in Manual mode, the horizontal and 
vertical sharpness can be adjust between 0~63. 

 

Slow AE: Adjust the exposure time, from  1~48 options.  The 
higher the value, the longer the exposure time is, and vice versa. 

 

FNR: Off, Manual, Auto 1, Auto 2. Auto 3. In Manual mode, FNR 
level value is 0~15 levels options. 

 

Max AGC: 0~48 options. 

 

AGC comps: Set the AGC compensation, 1~15 adjustable. 

 

Defog:  Select Off, Weak, Medium, Strong, Auto.  When the 
function is turned on, the contrast can be adjusted, so as to increase 
the clarity of the video. 

 

Color level: when the Defog  function  is  set as Weak, Medium, 
Strong, or Auto, the color level can be set in 0~128. 

 

Lum Mode: Off, Enhanced, Reduction or Auto Reduction options. 

 

Enhanced level: 0~255 options  when the Lum mode is set as 
Enhanced. 

Содержание Surveyor MKII Series XX282-40-01

Страница 1: ...d in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc Tel 631 952 2288 Fax 631 951 2288 Toll Free 8...

Страница 2: ...emarks that may appear belong to their respective proprietors FCC Warning The Surveyor MKII HD Network Domes comply with the FCC rules Operation is subject to the following two conditions This device...

Страница 3: ...from ground and entrance Refer to qualified personnel for all service matters Save product packaging to ensure availability of proper shipping containers for future transportation The power supply of...

Страница 4: ...8 3 3 7 IGMP 8 3 3 8 SIP 8 3 3 9 MDA 9 3 3 10 DDNS Setting 9 3 3 11 UPnP Setting 9 3 3 12 IP Filter Setting 9 3 4 Camera Settings 10 3 5 Audio Video 11 3 5 1 Video Settings 11 3 5 2 OSD 11 3 5 3 Moti...

Страница 5: ...og function IP67 environmental rating with built in heater and air cycle system and freeze proof 1 3 Product Specifications Lens Optical Zoom 30X Aperture Focal Length F1 4 F4 6 f 4 4 132 0mm Angle of...

Страница 6: ...Chapter II IE Browser Setting The user must set the IE browser and system before attempting to view the video When setting the IE browser note that the dome supports IE browser versions of Internet Ex...

Страница 7: ...ning the software users should use the default admin username and password The default User is ADMIN uppercase case sensitive Password 1234 Input the correct user name and password and then press OK t...

Страница 8: ...ion and privacy mask functions are enabled in the Audio video interface Refer to the sections 3 5 3 and 3 5 4 for details In the Live view interface users can perform PTZ control call up PTZ functions...

Страница 9: ...ed Note Available only for the admin Factory Settings Surveyor MKII HD series domes provides an online reset function which greatly facilitates reset adjustment Click Maintain current IP so the IP add...

Страница 10: ...e turned On or Off as required 3 3 2 FTP Figure 3 11 FTP settings Surveyor MKII HD series domes support the function of alarm associated FTP image unloading automatically capture images when alarm occ...

Страница 11: ...ethod and enter the user name and password 3 3 6 QoS Figure 3 15 QoS settings Users can set the network service quality in the QoS setting interface There are 4 network Qos modes to be selected 1 Norm...

Страница 12: ...ame System DDNS can enable constant synchronization of the host name and the dynamic IP address Users only need to input the dynamic domain name to connect to a network camera instead of memorizing th...

Страница 13: ...ue light AGC can be set Exposure Parameter settings are shown below Mode Set exposure mode Auto low Auto medium Auto high Auto D N Shutter Exposure Level In Shutter mode set the Level and select from...

Страница 14: ...CBR constant bit rate and Dynamic options With variable bit rate the system can automatically adjust the bandwidth of the images per the complexity of the images In practical use the complexity of the...

Страница 15: ...OFF and then click the button Save 3 5 3 Motion Detection Figure 3 28 Motion detection settings Motion detection function is supported Up to 4 motion zones can be configured If the zone number is alre...

Страница 16: ...t position 7 Press Delete button to delete the selected preset 8 Press Delete all button to delete all the presets 3 6 2 Scan Select Scan tab and the interface is shown as follows Figure 3 32 Scan 1 S...

Страница 17: ...eriod of time In the setting interface users can set return time action No 1 32 preset No 1 4 Auto tours and No 1 4 Scan are options and decide whether to return to the position before powering off 3...

Страница 18: ...ngle normal far vision 3 7 Schedules Click Schedule on the left navigation bar to display the Schedules interface shown below Figure 3 38 Time function In Mode setting the Act mode status and effectiv...

Страница 19: ...e can be set Users can select the alarm period For example if Sunday is checked then on each Sunday the alarm settings will be in effect in the set time if Everyday is selected then the alarm settings...

Страница 20: ...s operators or viewers and change their passwords The user name ADMIN cannot be changed but it is recommended to change the ADMIN password for increased security The system supports up to 8 users The...

Страница 21: ...TZ control tab to expand the PTZ control interface as shown below Figure 4 1 PTZ control interface In the interface users can perform PTZ control iris adjustment focus zoom adjustment and also set the...

Страница 22: ...ere of the selected area with the mouse the target area will be centered on the video display screen Figure 4 4 Dragging the frame with mouse Figure 4 5 Selected area zoom and centered When the option...

Страница 23: ...y interface right click the window and select Snapshot in the popped up menu then the current image can be saved to the local PC For instruction about the snapshot saving path please refer to the sect...

Страница 24: ...V1 0 1511...

Страница 25: ...VICON INDUSTRIES INC For office locations visit the website www vicon security com...

Отзывы: