Chapter I System Introduction 

1.1 Product Description 

The Surveyor MKII HD Network Dome provides users with a high-

definition, high frame rate and high SNR real-time images camera 

dome system.   

 

Surveyor MKII HD Network Domes use 1/3" progressive scanning 

CMOS sensors, with a built-in 30X optical zoom lens. 

 

Surveyor MKII HD series domes

 

facilitate setup and operation via 

web interface. Under PTZ control status, it has the features of zoom 

area and image PTZ control. 

 

Surveyor MKII HD series domes provide exceptional AI (artificial 

intelligence) functions such as preset, auto tour, scan and autoscan, 

timing tour, power-on reset, etc. In H.264 real-time video scanning, 

snapshots and local recording are supported. 

 

1.2 Product Features 

 

Support camera modules with 30X optical zoom lens 

 

Full HD IP video output, resolution up to 1920 × 1080 @ 30fps   

 

Built-in 1/3" progressive scan CMOS, auto varifocal lens 30X 
optical zoom 

 

H.264 high profile/M-JPEG dual-stream compression 

 

Onvif Profile S compliant 

 

Remote PTZ control via network 

 

Support IP filter 

 

Support RS485 control 

 

Support area zoom and image PTZ control 

 

Support digital zoom 

 

Support OSD 

 

Support image flip 

 

Multiple white balance modes 

 

PC recording 

 

SD card storage 

 

Support Preset/Scan/Auto tours/Autoscan/Tour/Timing 
tour/Power-on reset 

 

Privacy mask 

 

Motion detection 

 

4 alarm inputs and 1 relay output   

 

Two-way audio, G711-U 

 

Remote upgrade 

 

Support defog function 

 

IP67 environmental rating, with built-in heater and air cycle 
system and freeze-proof 

 
 
 
 
 

 

1.3 Product Specifications 

Lens

 

Optical Zoom 

30X 

Aperture/ 
Focal Length 

F1.4~F4.6, f=4.4~132.0mm 

Angle of View 

63.4° (Wide) ~ 2.3° (Tele) 

Min. Work 
Distance 

0.01m (Wide) ~ 1.5m (Tele) 

Camera

 

Scanning System 

Progressive scanning 

Image Sensor 

1/3" CMOS 

Sensitivity   

Color mode:   
0.4 lux @ F1.4 (1/30s, 350mV equiv., AGC-Gain: 48dB) 
0.1 lux @ F1.4 (1/8s, 350mV equiv., AGC-Gain: 48dB) 
B/W mode: 
0.01 lux @ F1.4 (1/8s, 350mV equiv., AGC-Gain: 48dB) 

S/N Ratio 

>50dB 

Video

 

Effective 
Resolution 

2.0 MP 

Video 
Compression 

H.264 high profile/M-JPEG 

Maximum 
Resolution 

1920×1080 @ 30fps 

Output Bit Rate 

Variable bit rate;   
Constant bit rate: 256Kbps~10000Kbps 

Network Delay 

<300ms 

Audio

 

Audio 
Compression 

G.711-U 

Audio port 

1 input, linear level, impedance: 1kΩ;

 

1 output, linear level, impedance: 600Ω

 

Storage

 

Built-in Storage 

With an embedded SD card slot, it is recommended to 
use an SD card up to 32G 

IP

 

Network Port 

1*10M/100M Ethernet port, self-adaptive, RJ-45 

Network 
Protocol 

IPv4, TCP, UDP, IGMP, DHCP, FTP, SNMP(v3), SMTP, 
NTP, RTP, RTSP, RTCP, HTTP, HTTPS, TSL, SSL, 
802.1X, QoS, PPPoE, DNS, ARP, ICMP 

Programming 
Interface 

NTCIP, Onvif profile S 

Operational

 

Pan Speed 

400°/s (Max.)     

Tilt Speed 

150°/s (Max.)     

Preset Speed   

Up to 1s 

Preset Accuracy 

0.5° 

Pan Travel 

360° continuous 

Tilt View 

-2.5 to 90° 

Presets 

255 

Auto tours 

Scans 

Tours 

6 (each tour can be associated with 14 acts, including 
preset 1~32, Auto tours 1~4, Scan 1~4) 

Home 

Yes 

Time Tour 

Yes 

Autoscan 

Yes 

Motion 

 

Yes, 4 areas 

Privacy mask 

Yes, 4 areas 

Alarm 

4 alarm inputs, 1 relay output 

Area Zoom 

Yes 

Web Server 

Yes 

Remote 

 

Yes 

Содержание Surveyor MKII Series XX282-40-01

Страница 1: ...d in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc Tel 631 952 2288 Fax 631 951 2288 Toll Free 8...

Страница 2: ...emarks that may appear belong to their respective proprietors FCC Warning The Surveyor MKII HD Network Domes comply with the FCC rules Operation is subject to the following two conditions This device...

Страница 3: ...from ground and entrance Refer to qualified personnel for all service matters Save product packaging to ensure availability of proper shipping containers for future transportation The power supply of...

Страница 4: ...8 3 3 7 IGMP 8 3 3 8 SIP 8 3 3 9 MDA 9 3 3 10 DDNS Setting 9 3 3 11 UPnP Setting 9 3 3 12 IP Filter Setting 9 3 4 Camera Settings 10 3 5 Audio Video 11 3 5 1 Video Settings 11 3 5 2 OSD 11 3 5 3 Moti...

Страница 5: ...og function IP67 environmental rating with built in heater and air cycle system and freeze proof 1 3 Product Specifications Lens Optical Zoom 30X Aperture Focal Length F1 4 F4 6 f 4 4 132 0mm Angle of...

Страница 6: ...Chapter II IE Browser Setting The user must set the IE browser and system before attempting to view the video When setting the IE browser note that the dome supports IE browser versions of Internet Ex...

Страница 7: ...ning the software users should use the default admin username and password The default User is ADMIN uppercase case sensitive Password 1234 Input the correct user name and password and then press OK t...

Страница 8: ...ion and privacy mask functions are enabled in the Audio video interface Refer to the sections 3 5 3 and 3 5 4 for details In the Live view interface users can perform PTZ control call up PTZ functions...

Страница 9: ...ed Note Available only for the admin Factory Settings Surveyor MKII HD series domes provides an online reset function which greatly facilitates reset adjustment Click Maintain current IP so the IP add...

Страница 10: ...e turned On or Off as required 3 3 2 FTP Figure 3 11 FTP settings Surveyor MKII HD series domes support the function of alarm associated FTP image unloading automatically capture images when alarm occ...

Страница 11: ...ethod and enter the user name and password 3 3 6 QoS Figure 3 15 QoS settings Users can set the network service quality in the QoS setting interface There are 4 network Qos modes to be selected 1 Norm...

Страница 12: ...ame System DDNS can enable constant synchronization of the host name and the dynamic IP address Users only need to input the dynamic domain name to connect to a network camera instead of memorizing th...

Страница 13: ...ue light AGC can be set Exposure Parameter settings are shown below Mode Set exposure mode Auto low Auto medium Auto high Auto D N Shutter Exposure Level In Shutter mode set the Level and select from...

Страница 14: ...CBR constant bit rate and Dynamic options With variable bit rate the system can automatically adjust the bandwidth of the images per the complexity of the images In practical use the complexity of the...

Страница 15: ...OFF and then click the button Save 3 5 3 Motion Detection Figure 3 28 Motion detection settings Motion detection function is supported Up to 4 motion zones can be configured If the zone number is alre...

Страница 16: ...t position 7 Press Delete button to delete the selected preset 8 Press Delete all button to delete all the presets 3 6 2 Scan Select Scan tab and the interface is shown as follows Figure 3 32 Scan 1 S...

Страница 17: ...eriod of time In the setting interface users can set return time action No 1 32 preset No 1 4 Auto tours and No 1 4 Scan are options and decide whether to return to the position before powering off 3...

Страница 18: ...ngle normal far vision 3 7 Schedules Click Schedule on the left navigation bar to display the Schedules interface shown below Figure 3 38 Time function In Mode setting the Act mode status and effectiv...

Страница 19: ...e can be set Users can select the alarm period For example if Sunday is checked then on each Sunday the alarm settings will be in effect in the set time if Everyday is selected then the alarm settings...

Страница 20: ...s operators or viewers and change their passwords The user name ADMIN cannot be changed but it is recommended to change the ADMIN password for increased security The system supports up to 8 users The...

Страница 21: ...TZ control tab to expand the PTZ control interface as shown below Figure 4 1 PTZ control interface In the interface users can perform PTZ control iris adjustment focus zoom adjustment and also set the...

Страница 22: ...ere of the selected area with the mouse the target area will be centered on the video display screen Figure 4 4 Dragging the frame with mouse Figure 4 5 Selected area zoom and centered When the option...

Страница 23: ...y interface right click the window and select Snapshot in the popped up menu then the current image can be saved to the local PC For instruction about the snapshot saving path please refer to the sect...

Страница 24: ...V1 0 1511...

Страница 25: ...VICON INDUSTRIES INC For office locations visit the website www vicon security com...

Отзывы: