![Vicon RV 1601 Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/vicon/rv-1601/rv-1601_operation-manual_1012863074.webp)
Chapter 10
G0201WAD3EN
72
net wrap
10.8 Electronic settings of the net wrap -
AUTOFORM
10.8.1
Changing the number of wraps
1
Select net wrap push button
(if still required).
2
With button
select wrapping programme P5.
3
The number below the lh picture gives the number of
net wraps.
4
Push button
till the value underneath the lh picture
starts blinking.
5
Set the desired value pushing the buttons
and
.
6
Confirm that new value pushing button
.
10.8.2
Resetting the net used indication
The number of metres net used since the last resetting
is shown on the display during work.
1
Select net wrap pushing button
(if still required).
2
With button
select wrapping programme P5.
3
The number below the rh picture gives the number of
metres of net used since the last resetting.
4
Push button
till the value underneath the rh picture
starts blinking.
5
Push button
, the value now is reset to zero.
6
Confirm by pushing button
.
10.9 Mechanical adjustments of the net
wrap
10.9.1
Adjustment of net brake
1
Slacken bolts (1) two turns only.
2
Take care that net brake is on full load (actuator fully
retracted) see position B.
3
Move radius of net brake in relation to radius disc.
4
Tighten bolts (1).
10.9.2
Tension of the net brake
Net tension is adjusted through the net brake. Standard
setting is 20 mm (25/32") with the spring in the last but one
position at the front side.
The above-mentioned setting is a nominal value. This
value depends on e.g. quality of the net, wastage.
If the brake is still cold wrap with lower rpm till the
brake has reached operation tamperature.
W
A0022
1
A
B
20 mm
W
A0067
Содержание RV 1601
Страница 1: ...G0201WAD3EN RV 1601 RV 1901 Operation manual WA0080 ...
Страница 2: ......
Страница 4: ......
Страница 8: ...G0201WAD3EN 6 Preface ...
Страница 106: ...G0201WAD3EN 104 ...
Страница 107: ......