![Vicon RV 1601 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/vicon/rv-1601/rv-1601_operation-manual_1012863042.webp)
Chapter 6
G0201WAD3EN
40
electronic control system AUTOFORM
6.7.3
Baler shape sensor calibration
Ensure the chamber is empty.
1
Three times push button
.
2
Twice push button
, the shown actual value (e.g.
128) is then entered and confirmed.
The rotational sensors are positioned at the lh and rh side
inside the baler. This calibration compensates the lh and rh
sensors with respect to each other.
6.7.4
Correction of bale diameter
1
Four times push button
.
2
Change the value by pushing buttons
or
this
may be adjusted from +10 to -10 cm (+4" to -4").
3
Confirm new setting by pushing button
.
6.7.5
Bale growth sensor calibration
Attention:
Open tailgate, then place stop pin in the lower hole
in the lateral wall. Then lower the tailgate pressure-
less (floating position) till the tensioner arm rests on
the stop pin. This is the basic position for calibration.
1
Five times push button
.
2
Twice push button
the actual value is then entered
and confirmed.
6.7.6
Twine run control (option)
1
Six times push button
.
2
Set the value to 0 or 1 pushing the buttons
or
.
3
Confirm new setting by pushing button
.
0 =
sensor disengaged
1 =
sensor engaged
W
A0054
dD4
dD5
dD6
dD6
dD7
Содержание RV 1601
Страница 1: ...G0201WAD3EN RV 1601 RV 1901 Operation manual WA0080 ...
Страница 2: ......
Страница 4: ......
Страница 8: ...G0201WAD3EN 6 Preface ...
Страница 106: ...G0201WAD3EN 104 ...
Страница 107: ......