![Vicon RV 1601 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/vicon/rv-1601/rv-1601_operation-manual_1012863040.webp)
Chapter 6
G0201WAD3EN
38
electronic control system AUTOFORM
6.5.4
Net run
The net is running although it should not (e3):
How to proceed:
1
Check if net has been cut.
2
Check whether net is pulled by belt(s) and/or bale.
The net is not running although it should do so (this is
indicated some seconds after initiation of the wrapping
procedure) (e4).
How to proceed:
1
Check net routing and correct fault.
2
Proceed with job.
6.5.5
Bad electrical supply or connection(s)
How to proceed:
1
Check all electrical connections.
2
Check battery tension (voltage) (see 4.10)
3
Check function of rotational sensors, check cables for
broken leads and bad electrical connection(s).
6.5.6
Drive indication instead of bale shape
indication
There are two possible causes for malfunction of the bale
shape indication:
1
Bad electrical connection(s).
2
Calibration beyond reach of the rotational sensors.
In both cases the four arrow tips in the working display are
replaced by
one full arrow
. The arrow indicates the
direction in which the driver must steer to fill the bale
chamber uniformely.
How to proceed:
1
Check all electrical connections.
2
Re-calibrate the rotational sensors with an empty bale
chamber (see 5.7.3).
6.5.7
Non-confirmable error displays
Strong electromagnetic radiation / fields may generate
electronic errors. Non-approved transmitters may be the
cause. The system may show not identifiable errors: if the
error cannot be confirmed/identified at the machine, ignore
it and proceed your work.