Chapter 9
G0201WAD3EN
60
twine tie
9.7.2
Changing the flax wrapping pro-
gramme
Attention:
Flax twine tie programme only can work when elec-
tronic twine running sensors are installed and con-
nected!
-
The twine tie programme P4 (flax programme) can be
set as desired as well.
-
All dimension settings on the control box are metric
(length in cm: 1 cm = 10 mm = 25/64”,
1” = 2.54 cm; also see conversion table sect.
14.3)!
0
Adjustable are:
-
Distance of the side wraps to the side of the bale in cm
(1 cm = 25/64"), shown at the rh in the display;
-
Distance between the wraps when baling (e.g. 5 cm;
2");
-
Number of final wraps when bale has reached its final
diameter (center of the display);
-
Wrapping pattern (left side of display).
Procedure:
1
Push .
2
Four times push button
to move to twine tie pro-
gramme P4.
3
Select value to change by pushing button, value will
blink.
4
Change value by pushing buttons
and
.
5
Confirm new value by pushing button
.
5
2
2
2
4
20
23
W
A9946
W
A0015
5cm
BR9560