Input/Output setup is to setup the output status and the input’s signal
status. Users must setup the output status to correctly control the
external devices. Input is to detect the status of the device. When input is
triggered, then the system can corresponded according to the setting.
When enter this setup menu, it will be the setup of output. Users can use
leftward,
rightward to enter the input setup menu.
Output
There are 4 output control terminals. Each can be set independently.
When output status setup is “---” means no output. If setting is on,
means under normal condition relay output open, and if activated, then
the relay output short. If the setting is off, then under normal condition,
relay output short and if activated, then the relay output open.
S.M.A.R.T.(Smart Monitoring, Analysis, and Reporting Technology)
System will auto detect, analysis and reporting the status of HDD.
When there is any unusual situation, then an alarm will be outputted.
User will be able to use this output signal to control external alarm
equipment. There are 4 sets of relay output for selection. (Relay
equipment is optional)
Input
This system has 4 input terminals. Each input can be set
independently. Users can use
leftward,
rightward to
enter the different input setup menu. Setup menu as below:
IO SETUP : INPUT1
1. TRIGGER TYPE ---
2. ALARM SOUND ---
3. OUTPUT1 ---
4. OUTPUT2 ---
5. OUTPUT3 ---
6. OUTPUT4 ---
Trigger Type:
Input terminals are mainly connection to switching
devices. The device is separate into No (Open under normal
28