040106.04
13
vetus®
Connection kit for fuel tanks
11
10
7
6
13
8
12
7
9
8
8 mm
10 mm
15 mm
3
4
3
4
2
2
1
1
5
5
1 Fuel supply
2 Fuel return
3 Filling connection, ø 38
(1
1
/
2
”)/ ø 51 mm (2”)
4 Vent (hose pillar)
5 Earth connection (terminal tag)
6 Filler hose
7 Breather nipple
8 Vent hose, ø 16 mm (
5
/
8
”)
9 Goose neck
10 Odour filter
11 Fuel overflow
12 Breather / overflow pipe, ø 16 mm (
5
/
8
”)
13 Filler cap
2 7 Check
Check the system for any leaks. Extraction pressure 20 kPa (0.2 bar)
(4.4 psi).
Sticker
Apply the red ‘Diesel fuel tank’ sticker on the tank, the text must be
readable after installation of the tank and also affix the content sticker.
Fresh water tank
• Drinking water safe
• Meets KTW standard
• P max. 30 kPa (0.3 bar | 4.35 psi)
• Tank capacity of:
AT147583W.VE
Quality product by
vetus
, Schiedam
Designed and made in the Netherlands
Excellent
warranty
Worldwide
network
Diesel fuel tank
• According to ISO 21487
• 0613
AT147583F.VE
• Max. test pressure 30 kPa (0.3 bar | 4.35 psi)
• Tank capacity of:
• Max. 100 °C
• Max. fill-up height 3.5 m
Quality product by
vetus
, Schiedam
Designed and made in the Netherlands
Excellent
warranty
Worldwide
network
Waste water tank
• According to ISO 8099
• P max. 30 kPa (0.3 bar | 4.35 psi)
• 0613
• Tank capacity of:
AT147583B.VE
Quality product by
vetus
, Schiedam
Designed and made in the Netherlands
Excellent
warranty
Worldwide
network
42 litres
9.2
Imp.Gal.
| 11.1
US Gal.
61 litres
13.4
Imp.Gal.
| 16.1
US Gal.
88 litres
19.4
Imp.Gal.
| 23.2
US Gal.
170 litres
37.4
Imp.Gal.
| 44.9
US Gal.
215 litres
47.3
Imp.Gal.
| 56.8
US Gal.
335 litres
73.7
Imp.Gal.
| 88.5
US Gal.
110 litres
24.2
Imp.Gal.
| 29
US Gal.
390 litres
85.8
Imp.Gal.
| 103
US Gal.
xx litres
xx.x
Imp.Gal.
| xx.x
US Gal.
xx litres
xx.x
Imp.Gal.
| xx.x
US Gal.
xx litres
xx.x
Imp.Gal.
| xx.x
US Gal.
xx litres
xx.x
Imp.Gal.
| xx.x
US Gal.
137 litres
30.1
Imp.Gal.
| 36.2
US Gal.
xx litres
xx.x
Imp.Gal.
| xx.x
US Gal.
AT147583A.VE
Diesel fuel tank
• According to ISO 21487
• 0613
AT147583F.VE
• Max. test pressure 30 kPa (0.3 bar | 4.35 psi)
• Tank capacity of:
• Max. 100 °C
• Max. fill-up height 3.5 m
Quality product by
vetus
, Schiedam
Designed and made in the Netherlands
Excellent
warranty
Worldwide
network
xx litres
xx.x
Imp.Gal.
| xx.x
US Gal.
t
ip
!
Unpleasant smells may escape from the air breather nipple. This
can be prevented by installing an active charcoal filter (Vetus
Odour Filter (10)) in the vent hose (8). Consult the relevant man-
ual for installing the Vetus odour filter.
• Vent hose
Fit the vent hose (8). Use a fire-resistant hose with 16 mm (
5
/
8
”)
internal diameter.
When viewed from the tank, the vent hose should be fitted in a
continuously upwards slope.
• Fuel supply and return
Connect the fuel supply (1) and the fuel return pipes (2) to their
respective fittings.
Fit all hose connections using 2 stainless steel hose clamps!
All metal parts in the fuel system must be earthed in order to pre-
vent sparks caused by static electricity. Connect an earth wire to
the contact tongue (5) on the connector cover. Also connect an
earth wire to the filler cap. Use yellow/green insulated wire with a
core cross-section of at least 1 mm
2
( AWG 16).
2 6 Connecting the tank
• Filler cap
Fit the filler cap (13).
t
ip
!
When filling the tank, fuel can overflow from the filler cap and
spill onto the deck. This can be prevented by installing a Vetus
Fuel Overflow (11) between filler cap (13) and tank. Consult the
relevant manual for installing the Vetus fuel overflow.
• Filler hose
Fit a filler hose (6) between the filler cap and the tank. Use a
fire-resistant hose with an internal diameter of 38 mm (1
1
/
2
”)or
51 mm (2”). Install this hose in such a way that neither tank or filler
cap are mechanically stressed.
• Breather nipple
Fit the breather nipple (7) as high as possible above the level of
the top of the tank.
W
arning
Choose a location for the breather nipple at a place where
leaking fuel or vapour cannot get into the ship!
ENGLISH