Vess R2000 Series Product Manual
Promise Technologies
If a physical drive fails in a disk array and there is a spare drive of adequate capacity available, the controller
automatically rebuilds the array using the spare drive. In this example, physical drive 3 failed and the array is
rebuilt using physical drive 6, the revertible spare drive.
When the rebuild is complete, the spare drive has replaced the failed drive. In this example, failed drive 3 was
replaced by spare drive 6. The disk array now consists of physical drives 1, 2, 4, and 6.
There is no spare drive at this moment. Even if physical drive 5 is of adequate capacity, it has not been
designated as a spare, therefore the controller cannot use it as a spare.
1
2
3
4
5
6
Array
Drives
Содержание R2000 SERIES
Страница 1: ...ProductManual ...
Страница 2: ...Vess R2000 Series Product Manual Version 2 0 2014 PROMISE Technology Inc All Rights Reserved ...
Страница 79: ...iSCSI SAN data and management connections 52 Vess R2000 Series Product Manual Promise Technologies ...
Страница 81: ...iSCSI DAS data and management connections 54 Vess R2000 Series Product Manual Promise Technologies ...
Страница 83: ...Vess R2600i with SAS JBOD expansion 56 Vess R2000 Series Product Manual Promise Technologies ...
Страница 151: ...124 Vess R2000 Series Product Manual Promise Technologies Topology display ...
Страница 302: ...275 Product Manual NAS Function and Management Redundancy with port configuration ...
Страница 704: ... 2014 PROMISE Technology Inc All Rights Reserved ...