![Vess R2000 SERIES Скачать руководство пользователя страница 234](http://html.mh-extra.com/html/vess/r2000-series/r2000-series_product-manual_1008893234.webp)
207
Product Manual
WebPAM PROe - System Configuration
r
eduNdaNCy
C
heCk
oN
a
l
ogiCal
d
riVe
Redundancy Check is a routine maintenance procedure for fault-tolerant disk arrays (those with redundancy)
that ensures all the data matches exactly. Redundancy Check can also correct inconsistencies.
To run
Redundancy Check
on a logical drive:
1. Click the
Administration
tab.
2. Click the
Background Activities
icon.
The list of background activities appears.
3. Mouse-over
Redundancy Check
and click the
Start
button.
4. Check the boxes to the left of the logical drives you want to run.
5. Check the options you want:
•
Auto Fix
– Attempts to repair the problem when it finds an error
•
Pause on Error
– The process stops when it finds a non-repairable error
6. Click the
Confirm
button.
s
tOPPing
, P
Ausing
Or
r
esuMing
A
r
edundAncy
c
heck
To stop, pause or resume
Redundancy Check
:
1. Click the
Administration
tab.
2. Click the
Background Activities
icon.
The list of background activities appears.
3. Mouse-over Redundancy Check and click the
Stop
,
Pause
, or
Resume
button.
Содержание R2000 SERIES
Страница 1: ...ProductManual ...
Страница 2: ...Vess R2000 Series Product Manual Version 2 0 2014 PROMISE Technology Inc All Rights Reserved ...
Страница 79: ...iSCSI SAN data and management connections 52 Vess R2000 Series Product Manual Promise Technologies ...
Страница 81: ...iSCSI DAS data and management connections 54 Vess R2000 Series Product Manual Promise Technologies ...
Страница 83: ...Vess R2600i with SAS JBOD expansion 56 Vess R2000 Series Product Manual Promise Technologies ...
Страница 151: ...124 Vess R2000 Series Product Manual Promise Technologies Topology display ...
Страница 302: ...275 Product Manual NAS Function and Management Redundancy with port configuration ...
Страница 704: ... 2014 PROMISE Technology Inc All Rights Reserved ...