![Vess R2000 SERIES Скачать руководство пользователя страница 602](http://html.mh-extra.com/html/vess/r2000-series/r2000-series_product-manual_1008893602.webp)
575
Product Manual
RAID 10
A RAID 10 source logical drive can migrate to the following target logical drives:
Target Requirements
RAID 0
None.
RAID 1
None.
RAID 5
3 physical drives minimum, 32 maximum.
RAID 10 must have less than 16 physical drives.
RAID 6
4 physical drives minimum, 32 maximum.
RAID 10 must have less than 32 physical drives.
If existing physical drives have no unused space, add 1 or more physical
drives.
RAID 10
Add physical drives.
Even number of physical drives.
RAID 50
6 physical drives minimum, 32 per axle maximum.
RAID 60
8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or more physical
drives.
When you migrate RAID 10 logical drive, it becomes RAID 1E by default.
If you want a RAID 10 logical drive, there must be an even number of physical drives and you must specify
RAID 10 for the target logical drive.
Содержание R2000 SERIES
Страница 1: ...ProductManual ...
Страница 2: ...Vess R2000 Series Product Manual Version 2 0 2014 PROMISE Technology Inc All Rights Reserved ...
Страница 79: ...iSCSI SAN data and management connections 52 Vess R2000 Series Product Manual Promise Technologies ...
Страница 81: ...iSCSI DAS data and management connections 54 Vess R2000 Series Product Manual Promise Technologies ...
Страница 83: ...Vess R2600i with SAS JBOD expansion 56 Vess R2000 Series Product Manual Promise Technologies ...
Страница 151: ...124 Vess R2000 Series Product Manual Promise Technologies Topology display ...
Страница 302: ...275 Product Manual NAS Function and Management Redundancy with port configuration ...
Страница 704: ... 2014 PROMISE Technology Inc All Rights Reserved ...