![Vess R2000 SERIES Скачать руководство пользователя страница 334](http://html.mh-extra.com/html/vess/r2000-series/r2000-series_product-manual_1008893334.webp)
307
Product Manual
array will become offline.
The user can do an accept to acknowledge the incomplete condition of the
array, and try to recover the access to the array and logical drives on the
array, in other words, to bring the logical drives online. However, it is a high-
risk and non-revertible operation, and it may result in data loss.
Therefore, it is recommended to try to clear the condition first, e.g., to put the
missing drives back; or to roam the array back to the original controller and wait
until the migration completes.
transport
To gracefully make the array and the logical drives on the array
offline to get ready for transport the array to another subsystem.
untransport
Cancels the transport action on the array and the logical drives.
Brings the array back online in the original subsystem.
Not supported for HBA products.
online
To set all the dead physical drives of array online at a time.
-d <DA ID>
The disk array ID. Valid values are 0-255. Used to specify the
desired array ID when creating (add) an array.
Used to specify the array ID when listing array information
modifying, deleting, locating, accepting, adding or deleting a
logical drive. Only one array may be specified.
-p <PD ID list>
Used to specify which physical drives are to be used in an array.
Used in conjunction with -a add. PD IDs can be used singly or
separated by comma. Additionally a sequential group of physical
drives can be specified by placing a ~ between numbers such as
1~6. This will include physical drives 1,2,3,4,5,6.
-s “<option>=<value>”
Used to specify settings for an array. This is used when creating
(add) or modifying (mod) an array. These options are comma
separated.
Содержание R2000 SERIES
Страница 1: ...ProductManual ...
Страница 2: ...Vess R2000 Series Product Manual Version 2 0 2014 PROMISE Technology Inc All Rights Reserved ...
Страница 79: ...iSCSI SAN data and management connections 52 Vess R2000 Series Product Manual Promise Technologies ...
Страница 81: ...iSCSI DAS data and management connections 54 Vess R2000 Series Product Manual Promise Technologies ...
Страница 83: ...Vess R2600i with SAS JBOD expansion 56 Vess R2000 Series Product Manual Promise Technologies ...
Страница 151: ...124 Vess R2000 Series Product Manual Promise Technologies Topology display ...
Страница 302: ...275 Product Manual NAS Function and Management Redundancy with port configuration ...
Страница 704: ... 2014 PROMISE Technology Inc All Rights Reserved ...