There must be a minimum depth of 76 cm (30 in.) between the front of the rack and
the rear of the rack. Veritas recommends that two people install the rails; one person
at the back of the rack and one at the front. Veritas also recommends that two
people lift and place the storage shelf into the mounted rails.
To install storage shelf rails into a rack
1
Identify the front and the rear of each rail. The following illustration shows the
front of the left-hand and the right-hand rails. Red arrows show the pins that
fit into the rack.
2
Use the rack templates to align the rails with the rack holes.
3
Fold the templates along the dotted yellow lines to match the holes in the rack.
Be sure to use the same holes on each side of the rack.
89
Adding one or more storage shelves to an operating 4TB appliance that does not have any storage shelves
Installing the storage shelf rails
Содержание NetBackup 5240
Страница 1: ...NetBackup Appliance Hardware Installation Guide Release 2 7 3 NetBackup 5240 Document Revision 1 ...
Страница 4: ......
Страница 22: ...Preinstallation requirements Prerequisites for IPMI configuration 22 ...
Страница 42: ...Installation procedures Connecting a 4TB appliance to more than one storage shelf 42 ...
Страница 43: ...43 Installation procedures Connecting a 4TB appliance to more than one storage shelf ...
Страница 66: ...Installation procedures Accessing and using the Veritas Remote Management interface 66 ...
Страница 140: ...Adding storage shelves to an operating 4TB appliance that has at least one storage shelf attached Recabling 140 ...