7
Label the cable on the main board so that you can accurately reconnect it later.
8
Lift the rear of the duct up and towards the rear of the appliance. The MFBU
remains attached to the air duct.
9
Lift the duct out completely and set it aside in a safe location.
10
Locate the DIMMs.
The DIMMs are located on either side and in the middle of the two CPU heat
sinks. Some DIMM sockets are empty.
Each DIMM socket has an identifier on the main board that consists of a
two-digit alphanumeric character that indicates the channel and socket for each
DIMM. Socket identifiers have the format A1, A2, B1, B2, C1, C2, etc. The
letter defines the channel and the number indicates the socket.
75
Adding one or more storage shelves to an operating 4TB appliance that does not have any storage shelves
Installing the External Storage Kit components