By default, NIC1 (eth0) is factory set to IP address 192.168.229.233. This private
network address is reserved to provide a direct connection from a laptop to perform
the initial configuration. NIC1 (eth0) is typically not connected to your network
environment.
Once the initial configuration has been completed, you can connect NIC1 (eth0) to
an administrative network that does not provide any backup data transfer.
Note:
You cannot bond the copper 1 GbE or the 10-GbE ports that are installed in
the appliance chassis with fibre ports on PCIe 10-GbE cards.
See “Connecting the power cords” on page 48.
Connecting the power cords
Each appliance and each storage shelf contain two AC power supplies. To ensure
power redundancy, connect the power supplies on each component to separate
AC power sources.
Caution:
Do not turn on the power to any components while connecting the power
cords. The components must be turned on in a specific sequence to ensure correct
communication.
To connect the power cables
1
Verify that the AC power supply input for the appliance and for the storage
shelf is within one of these ranges.
■
100 - 127 VAC at 50/60 Hz
■
200 - 240 VAC at 50/60 Hz
2
For each device, obtain two power cords that are appropriate for your region
and equipment.
Installation procedures
Connecting the power cords
48
Содержание NetBackup 5240
Страница 1: ...NetBackup Appliance Hardware Installation Guide Release 2 7 3 NetBackup 5240 Document Revision 1 ...
Страница 4: ......
Страница 22: ...Preinstallation requirements Prerequisites for IPMI configuration 22 ...
Страница 42: ...Installation procedures Connecting a 4TB appliance to more than one storage shelf 42 ...
Страница 43: ...43 Installation procedures Connecting a 4TB appliance to more than one storage shelf ...
Страница 66: ...Installation procedures Accessing and using the Veritas Remote Management interface 66 ...
Страница 140: ...Adding storage shelves to an operating 4TB appliance that has at least one storage shelf attached Recabling 140 ...