correct layout.
4.8.4
Refit the glass panel and glass panel retaining
(Cont.)
trims. The fender and ash pan cover or fascia can now be re-positioned.
4.9
Replacing the Control Cable (SC models)
4.9.1
The control lever operating cable
can be seen running across the
base of the fire, below the burner.
To release the cable, unscrew the
cable securing screw located in the
centre of the aluminium operating
arm and pull the cable out from its
fixing hole. Release the other end
of the cable by pushing the cable
towards the right i.e. into the
operating arm so as to release the
tension. Pull the cable nipple out
of the retaining hole and remove
the cable through the slot in the
operating arm. See fig. 39 opposite
4.9.2
Hold the hexagonal control lever cable locking bush with a spanner
and unscrew the locking screw using a 2mm allen key to release the
cable from the control lever. The control cable can now be removed
from the cable guide tubes.
4.9.3
To fit the replacement cable, thread the end of the new cable into the
long length of p.t.f.e. sleeve (as supplied) , taking care not to kink the
sleeve. Now carefully feed the sleeve and cable into the left hand cable
guide tube until the ends emerge above the control lever. Now thread
the short length of p.t.f.e. sleeve over the end of the cable and thread
the sleeve and cable into the top of the short cable guide tube.
4.9.4
When the end of the cable emerges from the short cable guide tube,
locate the nipple on the other end of the cable into the locating hole in
the aluminium operating arm. Thread the free end of the cable into the
cable retaining hole on the operating arm, but at this stage do not
tighten the securing screw.
4.9.5
Fit the hexagonal control lever cable locking bush onto the control
lever and fit the control cable loosely into the bush in the gap between
the two lengths of p.t.f.e. sleeve. Ensure that the cable is located in the
retaining hole in the locking bush and tighten the screw sufficiently to
retain the cable but still allowing it to slide for adjustment.
40
Fig. 39