background image

4005323-01

P

ORTRAIT

Installation & Owner’s Manual

Direct Vent Gas Insert Fireplace

530INI (NG) & 530IPI (LPG)

This manual contains instructions to install the

 EN-

GINE ONLY. 

A front trim kit is

 REQUIRED 

to install 

the engine as it affects the framing cavity and posi-
tion of the engine. A barrier screen is provided with 
the front or trim kit. 

Refer to the manual supplied 

with the front for framing and 

fi

 nishing.

— Do not store or use gasoline or other 

fl

 ammable vapors and liquids in the 

vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

 

Do not try to light any appliance.

 

Do not touch any electrical switch; do 
not use any phone in your building.

 

Leave the building immediately.

 

Immediately call your gas supplier from 
a neighbor’s phone. Follow the gas 
supplier’s instructions.

 

If you cannot reach your gas supplier, 
call the 

fi

 re department.

— Installation and service must be 

performed by a quali

fi

 ed installer, service 

agency or the gas supplier.

Ce guide est disponible en français sur demande.

This appliance is only for use with the type 
of gas indicated on the rating plate. This 
appliance is not convertible for use with 
other gases, unless a certi

fi

 ed kit is used.

This appliance is a domestic room-heating 
appliance. It must not be used for any other 
purposes such as drying clothes, etc.
This appliance is suitable for installation in a 
bedroom or bed sitting room.

This appliance may be installed in an 
after-market permanently located, 
manufactured (mobile) home where not 
prohibited by local codes.

HOT GLASS

 WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN 

TO TOUCH GLASS.

DANGER

!

A barrier designed to reduce the risk of burns from the hot 
viewing glass is provided with this appliance and shall be 
installed for the protection of children and other at-risk 
individuals.

  

!

  WARNING

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 
could result in serious injury, death, or 
property damage.

INSTALLER

Leave this manual 

with the appliance.

CONSUMER

Retain this manual 

for future reference.

Please read this manual 
BEFORE installing and 
operating this appliance.

©2016, Miles Industries Ltd. All rights reserved.

Summary of Contents for PORTRAIT 530INI

Page 1: ...ble en fran ais sur demande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used...

Page 2: ...cking Pilot and Burner Flames 7 Using Handset Wall Holder 7 Replacing Batteries 8 Locating Lighting Operation and Rating Information Plate 8 Servicing Your Fireplace 8 Operating Your Fireplace 8 How t...

Page 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Page 4: ...ace A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at...

Page 5: ...to reduce the risk of burns Keep the remote control handset OUT OF REACH of children HOT HEARTH FLOOR The hearth or floor in front of the fireplace may become very hot when the fireplace heats Do not...

Page 6: ...ts of these products Brasso Polish Plus by Kelkem Cook Top Clean Creme by Elco White Off by Rutland Turtle Wax Do not clean the glass while it is hot Always securely replace the window and the barrier...

Page 7: ...Inspect the vent terminal outdoors regularly to make sure that dirt snow insects leaves shrubs trees do not obstruct it Examine the whole vent system regularly We recommend annually Using Handset Wall...

Page 8: ...e manual On Off switch see instructions on next page The appliance uses four 1 5 V AA alkaline batteries for its remote control receiver and one 9 V alkaline battery for its handset The batteries shou...

Page 9: ...s off when the handle is perpendicular with the pipe Owner s Information How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently You can use one of the two following methods to ensure that your...

Page 10: ...mum flame height NOTE Before using the remote control system for the first time the receiver and the handset must be synchronized See the sub section Set up Remote Control on page 36 of this manual Se...

Page 11: ...he hour Press small flame button to set the minute Press OFF or simply wait to return to MAN mode Double click large flame button Flame automatically goes to high fire HI will be displayed Manual Mode...

Page 12: ...programming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERA TURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large flame button to increase Nighttime Setback T...

Page 13: ...TIMER moon while the time flashes Press large flame button to set the hour Press large flame button to set the hour Press small flame button to set the minutes Press small flame button to set the minu...

Page 14: ...period of 6 hours the appliance goes into pilot mode NOTE In TEMP or TIMER modes the flame height will vary according to room temperature The appli ance will continue to work normally However if the r...

Page 15: ...Gas Conversion Kits 530NGK Gas conversion kit from LPG to NG 530PGK Gas conversion kit from NG to LPG Other Accessories 555CFK Circulating Fan Kit 567FGP Top Grille with logs and rocks ONLY 580RGL Ref...

Page 16: ...ou smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH ON OFF switch 1...

Page 17: ...ural gas insert installations Heater engine 530IPI is used for propane gas insert installations The supply pressure must be between the limits shown in the Ratings table on the previous page The suppl...

Page 18: ...ncluded or sold separately Front with Barrier Screen required sold separately 2 x 3 approved flex chimney liners running full length WARNING HOT HEARTH FLOOR The hearth or floor in front of the firepl...

Page 19: ...F P using 720SWK for units with logs or rocks only see installation instructions supplied with 720SWK Min 3 0 Max 5 0 Beyond 5 0 the sidewall terminal may be used but will require restrictors See 530...

Page 20: ...ptions Flashing 25 1 2 3 min bend radius 4 3 4 x 3 liners 4 3 4 x 3 liners 530CVA Co axial Vent Adapter 530 engine 40 max 8 min Approved co axial termination or approved co axial 4 3 4 x 3 to 6 5 8 x...

Page 21: ...es additional 1 1 2 38 mm cavity height 25 1 4 19 1 4 2 x 3 dia colinear vent 530 insert engine with standard co linear vent Ensure base of heater is flush with finished hearth height otherwise front...

Page 22: ...ial such as wood compressed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or un plastered Non combustible materials Material such a...

Page 23: ...mp sealant Four feet horizontal is permissible to allow for routing around masonry projections Do not bend flex pipe over a 45 degrees radius 1 Co linear venting may be converted to solid 4 x 6 5 8 co...

Page 24: ...ind out which position is optimal for each type of installation To fit the restrictors loosen the two center screws of the left and right inlet ports Place the restrictor assembly under the screw head...

Page 25: ...insert engine will fit behind any raised curb some curbs may be removed separately from the refractory base Only qualified licensed or trained personnel should install this appliance Installer READ T...

Page 26: ...inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimensions section...

Page 27: ...ottom of the window 3 Carefully lift the window Keep the window and bolts in a safe place Remove Burner Module It may be desirable to remove the burner module to gain access for gas fitting to install...

Page 28: ...f the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping scre...

Page 29: ...valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5kPa The appliance must be isolated from the gas supp...

Page 30: ...al 580RGL Reflective Glass Liner Set To install the 580RGL see the installation instructions provided with the kit 567FGP Top Grille At this point you can install the 567FGP if used logs or rocks vers...

Page 31: ...ase log 6 4 5 1 2 3 Burner SIDE VIEW Back Brick Burner bracket Rest the base log behind the burner on its bracket flange BASE LOG Firebox supports 1a 5 Locate the left side log on the ceramic pin on t...

Page 32: ...the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front coal 1 2 4 5 3 1a Burner SIDE VIEW Back Brick Burner bracket Rest...

Page 33: ...e sold separately fit it now See instructions supplied with the grille 3 Place the rear panel on the rear support as indicated Hold in place and go to next step 4 Place the left and then the right pan...

Page 34: ...the rocks L and R Those rocks don t have any peg or hole Install those rocks as indicated at the left and right of the rock pile positioning them so that the arrows underneath point to the front of t...

Page 35: ...dow correctly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is...

Page 36: ...over Check Operation Turn the fireplace flame up and down using the remote control to confirm that the full range of inputs is achieved see the remote control operation instructions on pages 10 14 Set...

Page 37: ...lled at the base of a light switch plate IMPORTANT The location of the remote control handset is important to assure proper temperature regulation To obtain a constant temperature we recommend that th...

Page 38: ...38 Wiring Diagram Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram QUALIFIED INSTALLER...

Page 39: ...ial Adapter 4 3 4 x 3 to 6 5 8 x 4 590CVA Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and...

Page 40: ...damage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances iii...

Page 41: ...able sleeve 4002244 35 Receiver G6R R3AM ZV CP 4001911 36 Handset G6R H3T5 ZV BJ 4001910 37 Wall mount holder 9000008 38 Wiring harness 4001187 39 Hot glass warning plate 4003093 Code Description Part...

Page 42: ...42 NG LPG Replacement Parts 34a 1 5 9 13 17 21 26 31a 31b 36 2 6 10 14 18 22 27 32 37 3 7 11 15 19 23 28 33a 33b 38 39 4 8 12a 12b 16 20 25 25a 25a 30 35 24 29 34 OWNER S INFORMATION...

Page 43: ...43 Replacement Parts 530RSK 530LSK 530CSK 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 OWNER S INFORMATION...

Page 44: ......

Page 45: ...ion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model N...

Page 46: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Reviews: