manualshive.com logo in svg
background image

INSTALLATION INSTRUCTIONS

AND OWNER’S MANUAL

DIRECT VENT ZERO CLEARANCE 

GAS FIREPLACE HEATER

MODEL SERIES:

MULTIFUNCTION REMOTE (MF)

DVLL48BP92(N,P)-1

DVLL60BP90(N,P)-1

   

GAS-FIRED

UL FILE NO. MH30033

This appliance may be installed in 

an aftermarket, permanently located, 

manufactured home (USA only) or mobile 

home, where not prohibited by local codes.
This appliance is only for use with the type 

of gas indicated on the rating plate. 
This appliance is not convertible for use 

with other gases, unless a certified kit is 

used.

WARNING

If not installed, operated and maintained 

in accordance with the manufacturer’s 

instructions, this product could expose 

you to substances in fuel or from fuel 

combustion which can cause death or 

serious illness.

WARNING

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 

could result in serious injury, death or 

property damage.

—  Do not store or use gasoline or other 

flammable vapors and liquids in the 

vicinity of this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do 

not use any phone in your building.

•  Leave the building immediately.

•  Immediately call your gas supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

•  If you cannot reach your gas supplier, 

call the fire department.

—  Installation and service must be 

performed by a qualified installer, 

service agency or the gas supplier.

  INSTALLER: Leave this manual with the appliance.

 CONSUMER: Retain this manual for future reference.

HOT GLASS

DO NOT TOUCH

NEVER

WILL

CAUSE BURNS.

GLASS

UNTIL COOLED.

ALLOW CHILDREN

TO TOUCH GLASS.

WARNING

A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.

NOTE:

 Barrier required, may be sold separately.

Содержание DVLL48BP92N-1

Страница 1: ...n serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to li...

Страница 2: ...stalled Accent Light assembly The DVLL48BP models do not include the Accent Light assembly However the LK20 Accent Light Kit may be purchased and installed during or after fireplace installation Instr...

Страница 3: ...Wall Thimble Spacer attached to fireplace 1 6 Cover Plate Battery Box 1 7 Remote 1 8 Junction Box Cover 1 9 Duplex Receptacle 1 10 Flue Restrictor Assembly 1 11 Battery Box 1 12 Grommet 5 8 DIA 1 A 10...

Страница 4: ...VENT VERTICAL TERMINATION 29 VERTICAL TERMINATION 30 31 DVVK 5F FLEX VENT INSTRUCTIONS 32 33 FRAMING AND FINISHING 34 35 LINER INSTALLATION 36 GLASS PLACEMENT 37 MULTIFUNCTION REMOTE OPERATING INSTRUC...

Страница 5: ...or use of the fireplace can cause serious injury or death from fire burns explosions or carbon monoxide poisoning The installation must conform with local codes or in the absence of local codes with t...

Страница 6: ...en Height without standoff 34 5 16 34 5 16 36 5 16 in 36 5 16 in Width 69 in 69 in 73 in 73 in Depth 18 5 8 in 18 5 8 in 18 5 8 in 18 5 8 in Gas Inlet Shutoff Valve pipe 1 2 in NPT 1 2 in NPT 1 2 in N...

Страница 7: ...ner or a Porcelain Liner The DVLL48BP fireplace is shipped with a factory installed metal liner If desired it can be replaced with one of the other liner options The fireplace must have a liner instal...

Страница 8: ...e remove the 11 screws holding rear blower access cover plate then lay the access plate on the floor See Figure 1 Figure 1 3 Use a rag to wipe the inside bottom of the fireplace where the blowers will...

Страница 9: ...wer base bracket is about even with the left edge of the access opening Route the wiring away from the blower wheel See Figure 5 Figure 5 8 Next install the right hand blower assembly towards the righ...

Страница 10: ...ets are pulled rearward against the bottom flange of the fireplace The magnets on the blower base bracket will keep the blowers in place See Figure 8 Figure 8 11 Re attach the Blower Access Panel with...

Страница 11: ...9 1 4 I Width from the left side of the box to the centerline of vent 30 9 16 36 9 16 J Depth from back of box to centerline of top vent 7 1 8 7 1 8 K Height from the bottom of the box to the gas line...

Страница 12: ...ING TO BOTTOM OF VENTED OPENING 57 5 8 MIN 146cm 65 MIN 165cm Figure 11 Mantel Chart TOP EDGE OF FIREPLACE OPENING H 22 34 12 A 3 MINIMUM NON COMBUSTIBLE MATERIAL ZONE INDEX LETTER DISTANCE FROM FIREP...

Страница 13: ...g this fireplace against an exterior wall insulate to applicable insulation codes When you install your Direct Vent Fireplace in Room divider or Flat on wall corner positions a minimum of 8 inches cle...

Страница 14: ...and horizontal side wall venting will help to determine the various vent lengths allowable The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace to the...

Страница 15: ...stance of 2 feet 61 cm from the center line of the terminal 24 in 61 cm 24 in 61 cm L Clearance above paved sidewalk or paved drive way located on public property 7 ft 2 13 m 7 ft 2 13 m E Clearance t...

Страница 16: ...s capped on the bottom in which condensation and foreign particles may collect Figure 16 Installing a New Main Gas Shut Off Valve Check Local Code Each fireplace should have its own manual gas shut of...

Страница 17: ...8 in w c 2 68 kPa for the purpose of input adjustment to a maximum of 14 0 in w c 3 484 kPa CAUTION If one of the procedures results in pressures in excess of 1 2 psig 14 in w c 3 5 kPa on the firepl...

Страница 18: ...hould be attached to the green ground screw See Figure 19 BLACK HOT BRASS SCREWS JUNCTION BOX GROUND SILVER SCREWS GREEN SCREW WHITE NEUTRAL 120 VOLT POWER SUPPLY Figure 19 Install the receptacle into...

Страница 19: ...be located inside the fireplace near the gas valve See Figure 22 Locate and install the 5 8in diameter plastic snap in grommet over the low voltage battery and interface extension harnesses at the rig...

Страница 20: ...or the requirements of local building codes Therefore you MUST check local building codes to determine the requirements to these steps A chase should be constructed in the manner of all outside walls...

Страница 21: ...or 1 2in set back depths See Figure 26 FLUSH SET BACK MIDDLE MOUNT BRACKETS 3 TOP FRONT EDGE OF FIREPLACE Figure 26 Vent Pipe Clearance Note Maintain one inch of clearance around vertical vent pipe S...

Страница 22: ...rfaces 1 A flat hard combustible or non combustible surface 2 A raised wooden platform VERTICAL 90 DEGREE ELBOW WITH HORIZONTAL TERMINATION 2 610mm 12 MINIMUM 305mm VERTICAL VENT REQUIRED MAXIMUM HORI...

Страница 23: ...2 in 11 in 13 1 2 in Figure 34 CORNER INSTALLATION VERTICAL 90 DEGREE ELBOW TO HORIZONTAL OUT THE WALL 12 in minimum rise before elbow NOTE DIMENSIONS SHOWN WITH FRAMING SET BEHIND THE FIREPLACE FACE...

Страница 24: ...ner flue joints do not require any sealant VENT SYSTEM IDENTIFICATION Special DV Vent Kits Available from Empire Comfort Systems Inc dealers DVVK 5RP Direct Vent Fireplace Vent Kit for Rear Vent 6 to...

Страница 25: ...as shown in Figures 38 39 Then re install the flue baffle REMOVE BAFFLE TO INSTALL FLUE RESTRICTOR FLUE RESTRICTOR Figure 38 REMOVE BAFFLE TO INSTALL FLUE RESTRICTOR FLUE RESTRICTOR Figure 39 Figure...

Страница 26: ...running parallel to vent termination U INSTRUCTIONS Instructions Original Graphics DVLL60BP DVLL Vent Cap Clearance 061515 Figure 42 Below Grade Installation When it is not possible to meet the requir...

Страница 27: ...f the termination must not be less than 7 feet 6 inches SPECIAL NOTE For each 45 elbow installed in the horizontal run the length of the horizontal run MUST be reduced by 18 inches Reduce by 3 feet fo...

Страница 28: ...IMUM Dimensions in inches 12 66 72 24 80 132 11ft 36 91 204 17ft 48 103 240 20ft Figure 46 Two 90 Elbows Note Subtract 3 feet from the total horizontal measurement for each 90 elbow installed horizont...

Страница 29: ...tal run is 100 of vertical but cannot exceed 20 feet Figure 50 Three 90 Elbows Note Subtract 3 feet from the total horizontal measurement for each 90 elbow installed horizontally Subtract 1 1 2 feet f...

Страница 30: ...hese cases increasing the vent height may solve this problem Installing the Vent System in a Chase A chase is a vertical box like structure built to enclose the gas fireplace and or its vent system Ve...

Страница 31: ...pear as rust spots or streaks and in extreme cases holes Replace damaged components should immediately 2 Remove the cap and shine a flashlight down the vent Remove any bird nests or other foreign mate...

Страница 32: ...7 5 FLEX VENT PIPE SPACER SPRING 8 FLEX VENT PIPE Figure 58 3 Attach a 6 inch piece of hard pipe to raise the connection point above the fireplace 4 Use existing 8 inch diameter inlet collar to attach...

Страница 33: ...nto the fireplace flue Secure flue adapter to the fireplace flue with a minimum of two screws provided See Figure 59 11 Attach the Outer Vent pipe to the 8 inch diameter collar on the fireplace with a...

Страница 34: ...s through an interior wall an exterior wall or a ceiling These firestops act as a firebreak heat shield and as a means to insure that minimum clearances are maintained to the vent system Horizontal Fi...

Страница 35: ...framed hole See Figure 64 If the area above the ceiling is an attic position and secure the firestop on top of the previously framed hole See Figure 65 NOTE Remove insulation from the framed area in t...

Страница 36: ...ON NOTE A liner is required for operation of this fireplace Refer to the instructions that came with your liner for proper installation DVP 48 60 LPZ Bronze Ridgeback Liner Kit Figure 66 DVP 48 60 LKR...

Страница 37: ...tall the two accent glass panels into the metal retainer bracket located above the accent lights The two glass panels will be placed so they meet together at the center of the bracket 5 Replace the li...

Страница 38: ...OPERATING THE REMOTE SYSTEM OR ACTIVATING MANUAL BYPASS OF THE REMOTE SYSTEM CAUTION PROPERTY DAMAGE HAZARD EXCESSIVE HEAT CAN CAUSE PROPERTY DAMAGE THE FIREPLACE CAN STAY LIT FOR MANY HOURS TURN OFF...

Страница 39: ...th a paper clip and the IFC module will beep three times to indicate the IFC module is ready to synchronize with the transmitter within ten seconds See Figure 72 Figure 71 SWI BUTTON Figure 72 5 With...

Страница 40: ...the Receiver confirms reception of the command Remote Control Display Figure 76 Remote Flame Control The Proflame has six flame levels With the system on and the flame level at the maximum in the fire...

Страница 41: ...e Figure 81 To adjust the set temperature press the Up or Down Arrow Buttons until the desired set temperature is displayed on the LCD screen of the Transmitter See Figure 82 Figure 81 Figure 82 Smart...

Страница 42: ...ngle beep will confirm reception of the command OFF Figure 85 OFF Figure 86 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS Remote Dimmer Control Light The auxiliary function controls the AUX power outlet...

Страница 43: ...ondary burner Pressing the Down Arrow Button will turn the secondary burner off A single beep will confirm the reception of the command OFF Figure 89 OFF Figure 90 Remote Auxiliary Relay Control optio...

Страница 44: ...to avoid unsupervised operation To activate this function press the MODE and UP Buttons at the same time See Figure 95 To deactivate this function press the MODE and UP Buttons at the same time OFF F...

Страница 45: ...he wall control or remote control OFF for two or three seconds and then restoring a power supply back on The return of the system to normal operation must be checked under safe conditions by the user...

Страница 46: ...r See maintenance page 79 Pilot not grounded well Check ground connections Sensor Wire loose Check sensor wire terminals Gas pressure incorrect Adjust gas pressure Pilot Gas Line bent or kinked Replac...

Страница 47: ...ocked orifice Check orifice opening Clogged or dirty burner ports Clean burner ports Faulty valve Replace valve High altitude Adjust orifice size for altitude Backfire of burner Blocked orifice Check...

Страница 48: ...urn off all electric power to the appliance if service is to be performed if applicable 2 Locate On Off gas cock and turn clockwise to OFF Do not force LIGHTING INSTRUCTIONS 1 STOP Read the safety inf...

Страница 49: ...36459 6 0217 Page 49 This page intentionally blank...

Страница 50: ...30 50 51 37 40 42 26 27 28 38 44 43 45 47 39 41 23 24 20 21 22 52 46 48 25 53 54 49 37 PARTS VIEW WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts s...

Страница 51: ...ot NAT 29 R10918 R10918 Pilot LP 30 34425 34425 Pilot Bracket 31 R11977 R10933 Gasket Venturi 32 R11978 R10432 Venturi Tube 90 Degree 33 R7624 R7624 Air Shutter 34 36441 35532 Bracket Orifice Holder 3...

Страница 52: ...rounded three prong receptacle Do not cut or remove the grounding prong from this plug CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dange...

Страница 53: ...ge the top of the door from the tab retainers on top of the firebox See Figure 97 CAUTION The glass door is wide and heavy and can be difficult to install or remove by a single person It is recommende...

Страница 54: ...a safe location Figure 101 4 If the Logs and Rock kit or the Ridgeback Liner is installed these must be removed from the fireplace Refer to the instructions supplied with these options for removal an...

Страница 55: ...P gas is heavier than air If you smell gas immediately shut off the manual valve in the gas piping to the fireplace or on LP at the tank Do not try to light any appliance Do not touch any electrical s...

Страница 56: ...ufacturer should be done by a qualified service person 4 Do not abuse the glass by striking or hitting it WARNING Do not use Ammonia based or abrasive cleaners on glass Do not attempt to clean glass w...

Страница 57: ...pair should be done by a QUALIFIED SERVICE PERSON The fireplace should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessi...

Страница 58: ...ped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a...

Страница 59: ...ovisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a min...

Страница 60: ...36459 6 0217 Page 60 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 61: ...36459 6 0217 Page 61 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 62: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Страница 63: ...se Empire will repair or replace at Empire s option Duties of the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the app...

Страница 64: ...mfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...

Отзывы: