background image

6.3

RE-ASSEMBLING THE CERAMICS AND FUEL BED - COAL

MODELS

a)

Remove the glass panel and retaining trims as detailed on page 11 &

12. Place the ribbed ceramic fuelbed base on top of the fuelbed

support and pull fully forwards to the burner.

Make sure that the

fuelbed base is located centrally in the fire box

.

Ensure that the

fuelbed base fit fully down onto the fuel bed support and is not

lodged on the burner. Ensure the air ports as indicated by the

arrows are not blocked by the fuel-bed matrix. See fig. 3 & 4

below.

Fig. 3

Fig. 4

50

NOTE : The position of the fuel-bed components are critical to the

performance of the product. Therefore please ensure that the fuel-bed

components are positioned as described in the following section prior to

requesting a service call due to soot build up, poor flame pattern etc.

Check air ports in fuel-bed base panel are not obstructed.

If these air ports are not in line with the holes in the fuel-

bed base matrix do not proceed with the installation

Air ports in Fuelbed base mounting panel

Содержание Frontier 3 HE

Страница 1: ...Maintenance User Instructions Hand these instructions to the user Model No s NHKC MN NHKC SN NHKC RN NHKP MN NHKP SN NHKP RN NHFC MN NHFP MN NHFC RN NHFP RN NHFC RN4 NHFP RN4 are only for use on Natur...

Страница 2: ...3 9 Checking for clearance of combustion products 35 Section 4 5 Maintenance 4 1 Removal of the Burner Assembly Manual Control models 36 4 2 Removal of the Piezo Igniter Manual Control models 37 4 3 R...

Страница 3: ...tandard trim no spacer 470mm Height with standard trim no spacer 586mm Depth overall without fender 180mm Depth Flush fit from mounting face to rear 180mm Depth Flush fit mounting face to rear 130mm w...

Страница 4: ...c Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appliance when installed in G B When Installing in I E please consult document I S 813 1996...

Страница 5: ...5mm of additional overhang over 150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are satisfied 1 Check...

Страница 6: ...E The front opening of the fire place must be between 370 and 450 mm wide and between 550 and 570mm high If the opening exceeds these dimensions then a surround must be constructed from suitable non c...

Страница 7: ...WALL METAL FLUE BOXES The appliance may be fitted to twin wall metal flue boxes conforming to the constructional requirements of BS 715 for example the Selkirk LFE 175 box The box must have a minimum...

Страница 8: ...nce has been tested for use in a pre cast flue block complying with BS EN 1858 In accordance with BS EN 1858 pre cast flues built with directly plastered faces front or rear are not correctly installe...

Страница 9: ...ers safety and in accordance with BS 5871 2 the fitting of a hearth panel or physical barrier should be carried out Should this advice not be followed however please give consideration to the safety o...

Страница 10: ...ed brick or stone flue insulated pre fabricated metal flue box to BS 715 BS EN 1856 2 When installing into 125mm 5 inch diameter lined brick or stone flue or insulated pre fabricated metal flue box an...

Страница 11: ...he four screws as indicated 2 off L H S and 2 off R H S See fig 6 below Fig 6 b Remove the left and right hand side glass securing brackets from the product They are secured via 2 off screws each side...

Страница 12: ...rds and clear from the firebox taking care not to damage the glass panel See fig 8 below Fig 8 d Remove the burner heat shield which is retained by 2 off screws as shown below in fig 9 Fig 9 12 Burner...

Страница 13: ...own below in Fig 10 this will allow removal of the complete burner unit from the firebox Fig 10 For all Remote Control models proceed as follows f Remove the two off screws from the left and right han...

Страница 14: ...le out from its fixing hole Release the other end of the cable by pushing the cable forwards to the right i e into the operating arm so as to release the tension Pull the cable nipple out of the retai...

Страница 15: ...n to the appliance should be made to the isolating inlet elbow using 8mm rigid tubing There must be no soldered joints within the firebox See fig 14 15 below for suggested concealed pipe layouts Fig 1...

Страница 16: ...tape as supplied Failure to seal these inlet apertures could lead to flame reversal which in turn will damage the burner and control systems of the product Fig 16 below shows a correctly sealed instal...

Страница 17: ...of the cables through one of the two holes on each side of the flue outlet shroud l Position the fire carefully on the protected surface of the hearth and reach into the fire opening Thread each of t...

Страница 18: ...of the fire the holes should be closed around the pipe to prevent leakage of air through the gap around the pipe q Refit the burner Fit the four retaining screws on manual control models or two screw...

Страница 19: ...meter b Turn on the main gas supply and carry out a gas tightness test c Depress the control knob and turn anti clockwise to the position marked pilot Hold in the control knob for a few seconds to pur...

Страница 20: ...t point screw Check the pressure test point screw for gas tightness with the appliance turned on using a suitable leak detection fluid or detector 2 5 GAS TIGHTNESS AND INLET PRESSURE REMOTE CONTROL M...

Страница 21: ...rts as indicated by the arrows are not blocked by the fuel bed matrix See fig 20 21 below Fig 20 Fig 21 21 Check air ports in fuel bed base panel are not obstructed If these air ports are not in line...

Страница 22: ...support onto the burner support as shown below in Fig 22 Fig 22 c Fit four large coals between the front rail and the fuel bed matrix as shown below in Fig 23 Fig 23 22 Positioning of front ceramic p...

Страница 23: ...o small coals at the end of the row as shown below in Fig 24 Fig 24 e Fit three large coals behind the front row using the ribs in the fuel bed base as a guide for placement as shown below in Fig 25 F...

Страница 24: ...nd of the row as shown below in Fig 26 Fig 26 g Fit the remaining 4 large coals as shown below in Fig 27 Fig 27 The exact position and fit of the coals may be very finely adjusted to give the most ple...

Страница 25: ...after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags clearly labelled as RCF waste RCF wa...

Страница 26: ...the arrows are not blocked by the fuel bed matrix See fig 28 29 below Fig 28 Fig 29 NOTE The position of the fuel bed components are critical to the performance of the product Therefore please ensure...

Страница 27: ...ed pebbles as shown below in fig 31 Ensure that the cut out in the rear face of the coals is positioned as indicated The 4 off specially shaped pebbles are packed in a bag with a label FR on them Fig...

Страница 28: ...and position on the three central ribs in the fuelbed as indicated in Fig 32 below Fig 32 e Select the two small pebbles and arrange along the second row of the fuelbed See fig 33 below Fig 33 28 3 of...

Страница 29: ...uel bed base in fig 34 below Fig 34 g Do a final check that the pebbles are layed out as shown below in Fig 35 Fig 35 The exact position and fit of the pebbles may be very finely adjusted to give the...

Страница 30: ...not smoking eating or drinking in the work area and always wash your hands before eating or drinking h Replace the glass panel and retaining trims as described on pages 11 12 NEVER USE THE FIRE WITHOU...

Страница 31: ...looking underneath the front ceramic rail above the burner heat shield at the front left hand side of the fuel When the pilot has lit continue to hold the control lever down for 5 10 seconds to allow...

Страница 32: ...IN VALVE knob set in the OFF position e Press and hold the STAR button and UP button on the remote hand set simultaneously see Fig 37 overpage for image of handset f The valve will then emit an audibl...

Страница 33: ...THE FIRE h Should the handset be misplaced you can turn the fire off by switching the ON OFF switch to the OFF position 3 5 FITTING THE TRIMS FRETS Quasar HE Models a Fit the outer trim assembly to th...

Страница 34: ...uter trim assembly to the firebox with the magnets provided c Place ashpan cover onto fascia 3 7 FITTING THE ONE PIECE HITW FASCIA S Frontier 4 Models a Hook the fascia onto the top mounting bracket f...

Страница 35: ...removed and the test repeated after the fire has cooled d If spillage persists the flue is not functioning correctly and a fault exists If after investigation the fault cannot be traced and rectified...

Страница 36: ...heets etc 4 1 2 Remove the trim Lift the fender and ash pan cover out of the way and put them in a safe location Remove the glass panel unscrewing the top and side retaining brackets see page 11 12 of...

Страница 37: ...4 Unscrew the control tap locknut from the front of the control panel and remove the control tap 4 3 5 To refit a control tap reassemble in reverse order noting that the control tap locates with a fla...

Страница 38: ...unscrew the cable securing screw located in the centre of the aluminium operating arm and pull the cable out from its fixing hole Release the other end of the cable by pushing the cable towards the r...

Страница 39: ...orrect coal pebble layout Refit the glass panel and glass panel retaining trims The fender and ash pan cover or fascia can now be re positioned 4 7 Replacing the battery SC models 4 7 1 Unscrew Batter...

Страница 40: ...able guide tubes 4 9 3 To fit the replacement cable thread the end of the new cable into the long length of p t f e sleeve as supplied taking care not to kink the sleeve Now carefully feed the sleeve...

Страница 41: ...ol Fires For Diagrams refer to section 2 5 1 Removing the RC Burner Assembly RC models 5 1 1 Prepare work area lay down dust sheets etc 5 1 2 Remove the trim Lift the fender and ash pan cover out of t...

Страница 42: ...ove the burner assembly as described in section 5 1 5 3 3 Loosen the pilot nut and remove the two screws retaining the pilot assembly Unscrew the thermocouple from the gas valve 5 3 4 Re assemble in r...

Страница 43: ...as a registered gas installer The part numbers of the replaceable parts are as follows these are available from your local stockist whose details may be found on the BFM Europe website address as per...

Страница 44: ...50mm No purpose made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is iss...

Страница 45: ...r by a registered gas installer and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for fallen debris or blockages which must be removed The...

Страница 46: ...to hold the control knob in for 5 10 seconds to allow the thermocouple to heat up if the pilot goes out when the control knob is released repeat the lighting sequence In the unlikely event of a failur...

Страница 47: ...latched if the pilot goes out when the control lever is released repeat the lighting sequence In the unlikely event of a failure of the igniter firstly check the operation of the 1 5V battery and if n...

Страница 48: ...disc set in the ON position d Switch the main valve knob to the OFF position Image above shows MAIN VALVE knob set in the OFF position e Press and hold the STAR button and UP button on the remote hand...

Страница 49: ...E TRYING TO RE LIGHT THE FIRE 6 2 4 SPILLAGE MONITORING SYSTEM Applicable to all models This appliance is fitted with a spillage monitoring system which shuts down the fire if the evacuation of combus...

Страница 50: ...ure the air ports as indicated by the arrows are not blocked by the fuel bed matrix See fig 3 4 below Fig 3 Fig 4 50 NOTE The position of the fuel bed components are critical to the performance of the...

Страница 51: ...oal support onto the burner support as shown below in Fig 5 Fig 5 c Fit four large coals between the front rail and the fuel bed matrix as shown below in Fig 6 Fig 6 51 Positioning of front ceramic co...

Страница 52: ...two small coals at the end of the row as shown below in Fig 7 Fig 7 e Fit three large coals behind the front row using the ribs in the fuel bed base as a guide for placement as shown below in Fig 8 Fi...

Страница 53: ...e end of the row as shown below in Fig 9 Fig 9 g Fit the rear row of 3 coals as shown below in Fig 10 Fig 10 The exact position and fit of the coals may be very finely adjusted to give the most pleasi...

Страница 54: ...after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags clearly labelled as RCF waste RCF wa...

Страница 55: ...cated centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner Ensure the air ports as indicated by the arrows are not blocked by...

Страница 56: ...d pebbles as shown below in fig 14 Ensure that the cut out in the rear face of the pebbles is positioned as indicated The 4 off specially shaped pebbles are packed in a bag with a label FR on them Fig...

Страница 57: ...and position on the three central ribs in the fuelbed as indicated in Fig 15 below Fig 15 e Select the two small pebbles and arrange along the second row of the fuelbed See fig 16 below Fig 16 57 3 of...

Страница 58: ...uel bed base in fig 17 below Fig 17 g Do a final check that the pebbles are layed out as shown below in Fig 18 Fig 18 The exact position and fit of the pebbles may be very finely adjusted to give the...

Страница 59: ...OR CRACKED 6 5 CLEANING THE FIRE WARNING Before attempting any cleaning operation ensure that the fire has been allowed to fully cool Consult your retailer to determine what trim fret fascia option w...

Страница 60: ...o pages 11 12 of this book for details on how to remove the glass panel Replacement of any other parts must be carried out by a competent person such as a registered gas installer The part numbers of...

Страница 61: ...accuracy of illustrations and descriptions contained in this book cannot be guaranteed Part No B 122490 Issue 2 BFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ www bfm europe com Te...

Отзывы: