g)
To reduce the heat input, press the “DOWN / STANDBY” button until the
flame reduces to the low rate heat input setting (3.5kW). If you continue
to hold the “DOWN / STANDBY” button, the burner flame will extinguish,
and only the pilot flame will remain lit. If you wish to turn off the
fire altogether, press the “STAR” / “OFF” button.
AFTER THE PILOT FLAME HAS BEEN EXTINGUISHED, IF YOU
WISH TO RE-LIGHT THE APPLIANCE YOU MUST WAIT AT LEAST
THREE MINUTES BEFORE TRYING TO RE-LIGHT THE FIRE.
6.2.4
SPILLAGE MONITORING SYSTEM - Applicable to all models
This appliance is fitted with a spillage monitoring system which shuts down the fire
if the evacuation of combustion products from the fire is affected by a partially or
fully blocked flue.
If this system operates the fire will go out. If this occurs, leave the fire for at least
three minutes then follow the lighting procedure as described in the previous
section.
In the event of repeated operation a registered gas installer must be
called to investigate and rectify the cause.
49
“STAR” / “OFF” button
“UP” button
“DOWN” / “STANDBY”
button
“LED” handset light
Fig. 2