CA

LI

ST

A

 91

V

04

_2

02

11

2_

EN

Summary of Contents for CALISTA 917

Page 1: ...CALISTA 917 V04_202112_EN...

Page 2: ...of smoke variable combustion rate The compatibility of the appliance with any exhaust fan should be ensured Exhaust fans have no impact on combustion if the combustion air inflow is ducted the air is...

Page 3: ...ss A Minimum distance between the glass pane of the appliance and all combustible materials 1000mm Minimum distance between the side of the appliance and any combustible materials dS 250mm Minimum dis...

Page 4: ...1 FASTENING HARDWARE INSTALLATION FLAT CEILING...

Page 5: ...1 FASTENING HARDWARE INSTALLATION SLOPING ROOF...

Page 6: ...ble to the wall type countersunk screws Check the presence of the gasket and the sealing flange behind CALISTA DIRECT CONNECTION WITHOUT TRIPLE WALL FLUE DUCT CONNECTION WITH TRIPLE WALL FLUE DUCT Rem...

Page 7: ...Fixing the lower element on the upper element 3 steel or stainless steel rivets Mounting clamp 3 INSTALLATION OF THE CEILING COVER PLATE 4 INSTALLATION OF FLUE DUCTS...

Page 8: ...astening hardware 3 countersunk head screws M8x20 Perform this same step for installing extensions 3 countersunk head screws M8x20 4m Anti sway system 6 INSTALLATION OF THE ANTI SWAY SYSTEM FREE STAND...

Page 9: ...6 2160mm 7 Assembly of the connection element in the appliance excluding the ducts and extensions installed in the previous steps 200mm 180kg 2120mm 7 CALISTA INSTALLATION ON EXTENSIONS AND DUCTS 7 1...

Page 10: ...7 5 7 4 Fixing the lower element on the upper element 3 steel or stainless steel rivets Mounting clamp Duct connection Fixing the Calista on the extension 3 countersunk head screws M8x20 180kg 360mm...

Page 11: ...4m 8 ADJUSTMENT OF WALL SUPPORTS WALL MOUNTED Fixing the bottom of the appliance to the wall using adjustable supports Screws to be chosen according to wall type 9 ANTI SWAY SYSTEM WALL MOUNTED...

Page 12: ...loser to the nozzle The glass screen cleaning is increased when the register moves closer to the door The bottom glass screen cleaning register s is accessible by removing Calista finishing grid Loose...

Page 13: ...12 2 11 12 INSTALLATION OF DEFLECTORS 12 1...

Page 14: ...t at least two logs with the exception of densified logs Burn wood with humidity 20 Increase the combustion air supply Clear the flue outlet of any disturbing element eg satellite dish etc Raise the c...

Page 15: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...