PART 1 - General information

 

7

INTENDED USE

VENDLET Standard may be used for moving clients to a lateral, 

prone, or supine position, from one side of the bed to the oth-

er, or, to reposition them further up in bed. VENDLET Standard 

may also be used in connection with mobilization in and out of 

bed.

VENDLET Standard protects the caregiver from physical strain 

and heavy lifting in connection with the handling of immobile 

clients. Clients are turned/handled by pressing a hand control 

whereby the caregiver may support the client and ensure their 

correct and comfortable positioning. This provides room for 

increased awareness in the care, which boosts employee job 

satisfaction and client well-being.

To the client, the turning process becomes uniform and steady 

as the sheet supports the body over its full length. 

Target group

The target group is adult clients who are being cared for, 

dressed, washed etc. in bed. This will often be clients who are 

lifted in and out of bed or clients who are mobilized using a 

standing aid. Hence, the user will typically be clients with few 

physical and/or cognitive resources and palliative clients.

VENDLET Standard is also suitable for clients at risk of devel-

oping pressure ulcers. The uniform and steady transfer with 

the sheet minimizes friction and the associated shear that can 

damage the tissue and cause pressure ulcers. Furthermore, 

VENDLET Standard is often seen to have a positive effect on 

clients suffering from spatial awareness.

The VENDLET Standard is intended for adult clients weighing 

between 30 and 250 kg, with a height above 146 cm and a 

body mass index (BMI) above 17. 

There are no contraindications for the use of VENDLET Stand-

ard . However, prior to the first use of VENDLET Standard, it 

is important to assess whether VENDLET Standard is suitable 

for the client in question. It may be necessary to take special 

precautions, for example if a client is very restless in bed or has 

an untypical anatomy.

Independent living

VENDLET Standard is not designed to be operated by the cli-

ents themselves. However, if a risk assessment made by the 

responsible healthcare professional evaluate, that the client is 

able to take part in the moving and handling procedures, e.g. 

by operating the hand control, this can be a part of the rehabil-

itative effort.

The risk assessment should evaluate the clients physical, 

cognitive and palliative resources. The risk assessment must be 

available by the bed and must be updated on a regular basis. 

Vendlet ApS cannot be held responsible for the risk assessment 

or conclusions based on this.

Staff

Before using VENDLET Standard, it must be ensured that the 

caregivers/operators have read “Part 2 – User manual” and 

that the manual and quick guide are available by the bed.

Environment

VENDLET Standard can be used in all application environments 

(1-5), e.g. hospitals, nursing homes and domestic / private 

homes. 

PRODUCT DESCRIPTION

VENDLET Standard consist of two bars fitted with motors. The 

bar on the left side of the client has a blue color marking and 

the bar on the right side of the client has a red color marking. 

Each motorized bar has a groove which makes it possible to at-

tach the edge strip of the turning sheet to the bars. When the 

bars are running, the turning sheet will be dragged between 

the two bars, making it possible to move it from side to side.

A slide sheet is inserted under the turning sheet in order to 

reduce the friction of the turning sheet against the mattress.  

Four corner posts are fitted with a build-in actuator in order to 

raise and lower the bars with the press of a button.

VENDLET Standard can be adjusted in height, which makes it 

easy to adapt the system to the individual mattress and bed.

Furthermore, VENDLET Standard consist of a control unit and 

a hand control. The control unit is placed underneath the bed, 

normally on the base frame.

When the bars are raised VENDLET Standard works as side 

rails.

VENDLET Standard is telescopic in length and can be extended 

from 200 to 220 cm.

Содержание STANDARD

Страница 1: ...VALUE IN CARING MANUAL STANDARD...

Страница 2: ...ients in bed Classification rule Class I acc to rule 1 and 13 of annex VIII in EU 2017 745 The product complies with the following standards EN 60601 2 52 2010 Medical electrical equipment Part 2 52 P...

Страница 3: ...manual must be followed Vendlet ApS shall not be liable should VENDLET Standard be used modified or assembled in a way that is not described in this manual This manual is divided into three parts Par...

Страница 4: ...EVENT OF AN INCIDENT 10 SYMBOLS 11 PART 1 General information PART 2 User manual OPERATION 12 How to use VENDLET Standard 12 Turning 12 Moving from one side of the bed to the other 13 Repositioning t...

Страница 5: ...l hand control 32 Battery backup 32 Side rail bumper 32 PART 3 Technical manual Attaching the turning sheet before use 19 What should I do if the turning sheet is rolled askew on the bars 19 Changing...

Страница 6: ...ng 34 MAINTENANCE CHECK 35 Annual check 35 Electrical parts 35 Mechanical parts 35 Sheets 35 Functional tests 35 Replacements of parts 35 TROUBLESHOOTING TECHNICIANS 36 TECHNICAL DATA 37 Battery backu...

Страница 7: ...lient is very restless in bed or has an untypical anatomy Independent living VENDLET Standard is not designed to be operated by the cli ents themselves However if a risk assessment made by the respons...

Страница 8: ...clicking the The emergency release nut must only be used in case of emer gency see page 21 or malfunction of the actuators VENDLET Standard hand control Power with light stop button Tighten the sheet...

Страница 9: ...Therefore long loose hair should be collect ed before moving and handling the client Be aware that the client does not get too close to the edge of the bed as there is a risk of falling out of the bed...

Страница 10: ...ra compression at the edge of the mattress When alternating air mattresses are used it should be possible to inflate the mattress to a firm state before VENDLET Standard is operated Soft mattresses wi...

Страница 11: ...After 2 min of continuous use it requires 18 min rest Max 350W 80 sec 175W 40sec 25 C In continuous use at 25 C 350 W can be supplied for 80 sec then the power consumption will be reduced to 175 W for...

Страница 12: ...with VENDLET Standard enables caregivers to work on a one to one basis one hand is used to operate the hand control and the other hand is free to guide the arms and legs of the client In order to impr...

Страница 13: ...he button to reduce speed 4 Press the or button on the hand control to move the client to the side towards you 8 The client now lies on his her right side 9 Press the and button to slacken the sheet b...

Страница 14: ...r end of the bar 4 1 Turn VENDLET Standard on by double clicking the button 2 Press the and button to to lower the bars if they have been raised 3 If necessary press once or twice on the button to red...

Страница 15: ...his her side 4 Place the sling along the back of the client and make sure that the sling is centred and correctly placed in accordance with the instructions of the sling manufacturer 4 5 Use the VENDL...

Страница 16: ...is room for breathing 7 To return to a supine position press the button to raise the red bar and press the button to wind the tur ning sheet onto the red bar VENDLET Standard now turns the client to s...

Страница 17: ...sure relieving properties of the mattresses To prevent interference with the function of alternating air mattresses the turning sheet must be sufficiently slackened before a client is left unattended...

Страница 18: ...side is facing upwards 1 2 2 Fasten the velcro straps around the edge of the mattress support platform It is important that the straps are fas tened around the edge of the platform under the mattress...

Страница 19: ...e strip at the opposite edge of the turning sheet into the groove on the other bar 6 Use this bar to pull in the turning sheet by pressing the or button until the sheet covers the mattress evenly with...

Страница 20: ...g sheet onto the bar 2 4 5 5 Use the opposite bar to move the client to a supine posi tion on top of the new and the old turning sheets 6 3 4 Allow approx half of the new turning sheet to roll onto th...

Страница 21: ...you do not have power 1 Manually lift the bar and directly afterwards activate the emergency release by pushing the emergency release nut upwards 2 Once the bar has been released continue pressing th...

Страница 22: ...uld Yes No 3 Are the nylon straps attached to the bed frame and all the support bars Yes No 4 Is the turning sheet in good condition and does the sheet run over the bars Yes No 5 Is the slide sheet fa...

Страница 23: ...re During washing all electrical sockets outlets in the control unit and the control unit extension must be fitted with either a cable or a socket cover plug to eliminate ingress of water Equally all...

Страница 24: ...en the client is lying in bed Is the turning sheet running under the bars The sheet must be over the bars Are all plugs properly connected on the control unit The hand control buttons are not working...

Страница 25: ...and contact the distributor in case of obvious damage Parts list 1 unit Blue side complete 1 unit Red side complete 1 unit Suspension bracket for control unit 1 unit Control unit 1 unit Control unit...

Страница 26: ...ttress and the side rail on both sides of the mattress If the distance is above 6 cm the risk of entrapment must be evalu ated for the specific combination of bed mattress patient and VENDLET system L...

Страница 27: ...the bed must be at least 317 kg to be able to handle a user weight of 250 kg Max user weight VENDLET Standard Other equipment Required Bed SWL 250 kg 42 kg 25 kg 317 kg In intensive care situations th...

Страница 28: ...in the bottom of the bracket Tighten the button head bolt evenly Tighten the bracket at the foot end 3 Place the corner post as close to the headboard as possi ble Fit the button head bolt at the bot...

Страница 29: ...at and horizon tal 2 If the mattress is an alternating air mattress make sure it s fully inflated 3 Place the bar in the highest position 4 Press the small button on the corner post 5 Simultaneously l...

Страница 30: ...The suspension bracket is now placed correctly Electrical parts Mounting the control unit 4 3 Attach the power cord to the control unit 4 Slide the control unit onto the suspension bracket till it cli...

Страница 31: ...s have plugs with yellow O rings these are connected to the yellow control unit colour codes Connecting the control unit The hand control should be connected before the power cable is connected to a m...

Страница 32: ...s be placed where it will be visi ble from the bed and in close proximity to the bed ADDITIONAL ACCESSORIES Additional hand control An additional hand control can be connected if a hand control os req...

Страница 33: ...c parts intact and without signs of wear Are all wires intact Do both bars slacken and tighten the sheet Does the timer activate when the button is pushed twice within 2 seconds Does the timer turn of...

Страница 34: ...the bolts in the mounting plates and turn them aside to lift VENDLET Standard off the bed frame Optionally use the mounting trolley to transport VENDLET Standard to a new destination Storage Store VE...

Страница 35: ...end Check all cables plugs and relief cables for damage Check whether the cables are properly secured Check whether the cables are prop erly secured and not hanging loose Check if the actuators run u...

Страница 36: ...ature Switch the plugs of the two bars If the same bar still does not work then the motor of that bar is defective If the other bar is not working then the hand control or the control unit is defectiv...

Страница 37: ...EU 2017 745 VENDLET Standard is a class I product VENDLET Standard Product no 6300000 Max user weight 250 kg Control unit Power supply SMPS 350W Mains supply 100 220 Volt AC 60 Hz or 100 230 Volt AC...

Страница 38: ...This equipment is compliant with IEC 60601 1 2 meaning that no loss of essential performance is found due to electromag netic disturbances The essential performance of VENDLET Standard refers to cont...

Страница 39: ......

Страница 40: ...All rights reserved Copyright Vendlet ApS Vers 3 0 2021 11 Vendlet ApS Egelund 33 6200 Aabenraa Tel 96 31 00 50 vendlet vendlet dk www vendlet com Manufacturer MD...