4. The red side actuator cables have plugs with green O
rings; these are connected to the green control unit colour
codes.
6. The plugs on the red bar motor cables are fitted with a red
O ring; these are connected to the red control unit colour
code.
3. Now connect the actuator cables. The blue side actuator
cables have plugs with yellow O rings; these are connected
to the yellow control unit colour codes.
Connecting the control unit
The hand control should be connected before the power cable
is connected to a main plug.
1. Connect the hand control to the control unit in the socket
shown below.
2. Connect the control unit at this symbol to the control
unit extension at this symbol
5. The plugs on the blue bar motor cables are fitted with a
blue O ring; these are connected to the blue control unit
colour code.
7. Close the control unit.