VEMCO – VR100 Receiver Operating Manual – Page 14
14.
Enter the Minimum Period value.
15.
Enter the Maximum Period value.
16.
Press the right selection button to “Accept” this tag.
17.
If more tags are to be entered, repeat steps 3 to 16.
18.
Press the Menu button until the Main screen appears.
2.2.8 Enter slope and intercept for a coded sensor tag
The tag’s information that must be entered in the VR100 is found in the Transmitter Specification manual
shipped with the tags. See section 4.3.4.1 for more details.
From the Main menu:
1.
Select Config (right selection button).
2.
Press “4” on the keypad.
3.
Press “1” on the keypad.
4.
If a list of serial numbers appears, press the left selection button to select “New”. Otherwise, go to
Step 5.
5.
Enter the serial number of the tag and press “Next”.
6.
Enter the tag’s operating frequency.
7.
Select the code space from the list provided by pressing the up or down arrow until the correct code
space name is shown on the display.
8.
Enter the coded tag ID number.
9.
Enter the tag’s slope value.
10.
Enter the tag’s intercept value.
11.
Select the data type, temperature, depth or acceleration.
12.
Press the right selection button to “Accept” this tag.
13.
If more tags are to be entered, repeat steps 3 to 13.
14.
Press the Menu button until the Main screen appears.
NOTE: For coded two-sensor tags, two separate sensor tag entries are required – one for each tag ID
(sensor). Since the VR100 does not allow duplicate serial numbers in the sensor database, the serial
number for the second sensor entry must be different than the first sensor entry. We recommend that
you use the serial number provided on the specification sheet for the first sensor entry, and the same
serial number with a prefix for the second sensor entry. For example, using “20” as the prefix:
Sensor 1 SN: 1034857
Sensor 2 SN: 201034857