Criteria for Programming
(1) The keypad
MUST
be in Programming Mode for making Se�ng and Data Changes.
(2) Programming can be accomplished in workshop or at the installa�on site. All data are stored in a
non-vola�le memory and will not be lost in power off.
(3)
DO NOT
disconnect the keypad from power while in programming mode; otherwise could cause
a keypad memory error.
Enter and Exit Programming Mode
It is necessary to set the keypad in programming mode with the Master Code for all programming.
1. Enter programming mode with the master code and confirm it with
key.
For the owner’s convenience in programming at the first �me, a Master Code
has
been set before exit-factory.
Master Code
Confirm
--- Keypad is now in programming mode
2. Use the programming instruc�ons stated in “Programming Summary Chart”
to make change of
the keypad data. Programming can be done con�nuously one by one on the Loca�ons required
un�l finish.
3. Exit the programming mode by pressing the
key a�er all the required programming is finished.
NOTE:
●
For security reason, owner should program a new master code to replace the exit-factory master
code.
●
Once a new master code is programmed, the old master code is replaced.
●
Use DAP jumper to set keypad to programming mode if master code is forgo�en. See DAP
Jumper descrip�on for the details.
The DAP Jumper (Direct Access to Programming Mode) – If Master Code is Forgo�en
If the master code is forgo�en, use the DAP jumper (located on the main circuit board) to override
the forgo�en code and permit the keypad direct entry into programming mode. Apply the
procedures precisely as follows.
1. Disconnect the power supply.
2. Move the DAP jumper from OFF to ON.
3. Reconnect the power supply.
The keypad will start beeping.
4. Move the DAP jumper back to OFF posi�on.
The keypad will stop beeping as soon as the jumper is removed.
5. The keypad is now in the programming mode, ready to receive new programming data.
6. Re-program the keypad with the available op�ons shown on the “Programming Summary Chart”.
●
The opera�on of DAP jumper is for se�ng the keypad into programming mode only. It does not
affect the stored data in the programming loca�ons.
●
A�er the keypad is in programming mode, a new master code may be programmed to replace the
one that was forgo�en.
SETTING & PROGRAMMING
DAP
ON OFF
11