9 - EG IN
--
EGRESS INPUT
A Normally Open (N.O.) input terminal refers to (–) ground, with the help of a normally open
bu�on to ac�vate the Output 1 for the same �me period as like the user code. Egress bu�on is
usually put inside the house near the door.
More than one egress bu�ons can be connected in parallel to the terminal. Leave this terminal
open if it is not used.
10 : KEY ACT
--
KEYPAD ACTIVE OUTPUT
This is an NPN transistor open collector output with maximum ra�ngs of 100mA sink and 24V DC.
It switches to (–) ground for 10 seconds on each key touching This can be used to turn on lights,
CCTV camera, or buzzer to no�fy a guard. See Applica�on Hints for more informa�on.
11 : DU OUT --
DURESS OUTPUT
An NPN transistor open collector output. It switches to (–) ground a�er the Duress Code is
entered. Use it to trigger an alarm zone, an auto-dialer or turn on a buzzer to no�fy a guard. Ic
max: 100mA sink. Vc max: 24VDC.
12 : GND (-) --
COMMON GROUND
An auxiliary nega�ve common ground of the keypad.
13 : DOOR SENS --
DOOR POSITION SENSOR INPUT
A Normally Closed (N.C.) input terminal referring to (–) ground. With the help of a normally
closed magne�c door switch, the system monitors the posi�on of open or closed of the door and
will give the following func�ons:
NOTE:
Always connect this terminal to (–) ground if not used.
1) Door Auto Re-lock
The system will immediately relock the door a�er valid access has been gained before the end
of the programmed �me for output 1, that prevents unwanted "tailgate" entries.
2) Door Forced Open Warning
The keypad will generate door forced-open warning instantly if the door is forced to open
without a valid code user entry or egress input. The warning will last for 60 seconds and can be
stopped any�me with an user code for output 1. This func�on is selectable via the
programming op�ons at Loca�on 80.
3) Door Propped-up Warning
When the door is le� open longer than the allowable �me. The keypad will generate door
propped-up warning a�er the expiry of the pre-set door-open-�me un�l the door is closed
again. The door-open-�me is programmable from 1 to 999 seconds at Loca�on 9.
4) Inter-lock Control
The inter-lock control output goes to (–) while the door is open in order to give signal to disable
the other keypad in the inter-lock system.
●
●
●
●
●
5