D) Configura�on of Output Modes –
Installer Programming
(Default: Momentary, 1-second for all 3 outputs)
Loca�on
Code of Timing
Confirm
Comments
1 to 999
Loca�on
Code of Timing
Confirm
Comments
1 to 999
Output 2, Momentary Mode from 1 to 999 seconds
(default = 1 second)
Output 2, Start / Stop Mode (toggle)
Output 2, Start / Stop Mode (toggle) with 2-digit Accelerated Start Code
Output 2, Start / Stop Mode (toggle) with 3-digit Accelerated Start Code
E) False Code Lock-up & Repor�ng –
Installer Programming
(Default: 10 tries / 30 seconds)
Loca�on
Lock-up Modes
Confirm
Comments
1
10 successive false codes, keypad locks during 30 seconds
(default)
2
10 successive false codes, Duress Output actuates (switches to GND)
5 to 10
Selectable of 5 to 10 false code, keypad locks during 15 minutes.
Locking can be released at any �me with Super User Code
00
Disappearance of all the above securi�es
F) Door Forced-Open Alarm –
Installer Programming
(Default: Disabled)
Loca�on
Func�on Codes
Confirm
Comments
Door Forced-Open Warning disabled
(default)
Door Forced-Open Warning enabled, ac�ve �me is 60 seconds
G) Output Ac�va�on (Door Open) Announcer –
Installer Programming
(Default: 1 long beep)
Loca�on
Func�on Codes
Confirm
Comments
Output 1, Momentary Mode from 1 to 999 seconds
(default=1 second)
Output 1, Start / Stop Mode (toggle)
Output 1, Start / Stop Mode (toggle) with 2-digit Accelerated start code
Output 1, Start / Stop Mode (toggle) with 3-digit Accelerated start code
No no�fica�on.
2 short-beep is given when the door lock is opened.
1 second long beep no�fica�on is given when the door lock is
opened. It is good for locking device give no sound when it
ac�vates. Such as a magne�c lock
(default)
9