Outputs 1 & 2 can be programmed to trigger with the following op�ons. for a programmed length
of �me from 1 to 999 seconds; or to trigger ON and OFF in toggle with a user code; or to trigger ON
with an accelerated start code and OFF with an full digit user code.
Loca�ons
Time Length
Confirm
A)
1 – 999
B)
C)
D)
NOTE:
Programming Loca�ons:
●
Loca�ons 40, 41, 42 and 43
for Output 1
●
Loca�ons 50, 51, 52
and 53
for Output 2
The programming manner of the two outputs are exactly the same.
Programming Options for Outputs 1 & 2
(See “Programming Summary Chart” Section D for more
information) :
A) Loca�on 40 or 50 : Momentary Mode with �me length from 1 to 999 seconds (Default = 1 second)
The relay outputs can be programmed to work for a �me length from
to
seconds to
cope with the door opening required.
B) Loca�on 41 or 51 : Start / Stop Mode (toggle)
The relay outputs can be programmed to trigger ON (start) and OFF (stop) with a user code.
C) Loca�on 42 or 52 : Start / Stop Mode (toggle) with 2-digit Accelerated Code
The relay outputs can be programmed to trigger ON with only the first 2 digits of a user code and
OFF with a full user code.
Example:
a) User Code
8 3 2 1
is a full code, then the first 2 digit
8 3
is the accelerated code.
b) User Code
5 4 3 2 1
is a full code, then the first 2 digit
5 4
is the accelerated code.
D) Loca�on 43 or 53 : Start / Stop Mode (toggle) with 3-digit Accelerated Code
The relay outputs can be programmed to trigger ON with only the first 3 digits of a user code and
OFF with a full user code.
Example:
a) User Code
5 4 3 2 1
is a full code, then the first 3 digit
5 4 3
is the accelerated code.
b) User Code
9 2 7 0 5 3
is a full code, then the first 3 digit
9 2 7
is the accelerated code.
Configura�on of Output Modes for Outputs 1 & 2 (Loca�ons 40–43 & 50–53)